English
Language : 

GC120 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 120W Single Output Battery Charger
120W Single Output Battery Charger
GC120 series
Features :
2 stage charging characteristic
Universal AC input / Full range
Built-in active PFC function, PF>0.97
No load power consumption<0.5W
3 pole AC inlet IEC320-C14
Class I power ( with earth pin)
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Fully enclosed plastic case
2 color LED indicator for charging status
Approvals: TUV / UL / CB / FCC / CE
2 years warranty
ORDER NO.
OUTPUT CONNECTOR
GC120Axx-R7B (standard model)
4pin power din
GC120Axx-AD1 (optional model)
Anderson connector
GC120Axx- xx=12,24,48 ; =R7B,AD1
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
( for GC120Axx-AD1 only)
SAFETY
TUV / CB / FCC / CE
UL / TUV / CB / FCC / CE
SPECIFICATION
ORDER NO.
GC120A12-
GC120A24-
GC120A48-
OUTPUT
SAFETY MODEL NO.
DC VOLTAGE (Typ.)
GC120A12
13.6V
RECOMMENDED BATTERY
CAPACITY
Note.2
40 ~ 100Ah
CONTINUOS OUTPUT
CURRENT (Typ.)
7.5A
GC120A24
27.2V
20 ~ 65Ah
4.42A
GC120A48
54.4V
10 ~ 35Ah
2.21A
RATED POWER
102W
120.2W
120.2W
LED INDICATOR
Charging(CC) : RED Floating charging(CV) : GREEN
VOLTAGE RANGE Note.3 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97 / 230VAC PF>0.99 / 115VAC at full load
INPUT EFFICIENCY (Typ.)
86.5%
90%
91%
AC CURRENT
1.4A / 115VAC 0.7A / 230VAC
INRUSH CURRENT (max.) 70A / 230VAC
LEAKAGE CURRENT(max.) 0.75mA / 240VAC
OVERLOAD
90 ~ 110% rated output power
Note.4
Protection type : Constant current limiting recovers automatically after fault condition is removed
SHORT CIRCUIT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
OVER VOLTAGE
14 ~ 16.5V
29 ~ 33V
Protection type : Shut down o/p voltage, re-power on to recover
59 ~ 69V
OVER TEMPERATURE
100 10 (RTH2) detect on inside ambient temperature
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-30 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0~50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1012 (for GC120Axx-AD1 only), TUV EN60950-1 approved
SAFETY &
EMC
(Note. 5)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P: 3KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, FCC PART 15 class B / CISPR22 class B
Compliance to EN61000-3-2,3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
MTBF
400.7Khrs min. MIL-HDBK-217F(25 )
OTHERS
CONNECTOR
DIMENSION
PACKING
PLUG
CABLE
167*67*35mm (L*W*H)
0.62Kg; 20pcs/13.4Kg/0.9CUFT
See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. This is MeanWell's suggested range, please consult your battery manufacturer for their suggestions about maximum charging current limitation.
3. Derating may be needed under low input voltage. Please check the derating curve for more details.
4. Constant current operation region is within 50~100% rated output voltage.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:GC120-SPEC 2010-11-08