English
Language : 

FM90C Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 90WAC-DC Single Output Desktop
90W AC-DC Single Output Desktop
FM90C series
Features :
Universal AC input / Full range
No load power consumption<0.75W@240VAC
3 pole AC inlet IEC320-C6
Class I power (with earth pin)
Built-in active PFC function, PF>0.90
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: UL / CUL / TUV / CB / FCC / CE
1 year warranty
SPECIFICATION
TUV
SUD
GeprUfte
Sicherheit
ORDER NO.
FM90C12-P1M
FM90C19-P1M
FM90C24-P1M
SAFETY MODEL NO.
FDF0903-C
FDF0903-A
FDF0903-D
DC VOLTAGE
RATED CURRENT
Note.2 12V
6.60A
19V
4.75A
24V
3.75A
CURRENT RANGE
0~ 6.60A
0 ~ 4.75A
0 ~ 3.75A
OUTPUT
RATED POWER
80W
RIPPLE & NOISE (max.) Note.3 150mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
LINE REGULATION Note.5 1.0%
LOAD REGULATION Note.6 4.0%
SETUP, RISE , HOLD UP TIME 300ms, 50ms , 10ms at full load
90W
150mVp-p
3.0%
1.0%
2.0%
90W
150mVp-p
3.0%
1.0%
2.0%
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF 0.90/230VAC
INPUT EFFICIENCY (Typ.)
80%
80%
82%
AC CURRENT
1.3A/100VAC
INRUSH CURRENT (max.) 100A/240VAC
LEAKAGE CURRENT (max.) 0.75mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
110 ~ 150% rated output voltage
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 150% rated output voltage
Protection type : Clamp by zener diode
WORKING TEMP.
WORKING HUMIDITY
0 ~ + 50 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 3AXES 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note. 7)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:1.5KVAC; I/P-FG: 1.5KVAC
I/P-O/P, I/P-FG: 100M ohms/500VDC/25 /70% RH
Compliance to EN55022(CISPR22) class B, FCC part 15 class B
Compliance to EN61000-3-2,3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
30K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
PACKING
PLUG
CONNECTOR
CABLE
133*58*30mm (L*W*H)
406g; 32pcs/14.5Kg/CARTON
Standard type P1M: 2.5 * 5.5 * 11mm, tuning folk type center positive for stock ; Other type available by customer requested
Standard type UL1185, 16awg*4fts for stock ; Other type available by customer requested
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load.
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:FM90C-SPEC 2008-05-08