Features :
Universal AC input / Full range
2 pole AC inlet IEC320-C8
Class power (without earth pin)
Full output 3~48V safety approval
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
RCC control circuit and regulated
LED indicator for power on
Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE
1 year warranty
SPECIFICATION
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
ES18B03-P1J ES18B05-P1J ES18B07-P1J ES18B09-P1J ES18B12-P1J ES18B15-P1J ES18B18-P1J ES18B24-P1J ES18B28-P1J ES18B48-P1J
SAFETY MODEL NO.
ES18B03-033 ES18B05-050 ES18B07-075 ES18B09-090 ES18B12-120 ES18B15-150 ES18B18-180 ES18B24-240 ES18B30-280 ES18B48-480
DC VOLTAGE
Note.2 3.3V
5V
7.5V
9V
12V
15V
18V
24V
28V
48V
RATED CURRENT
2.72A
3.0A
2.0A
2.0A
1.50A
1.20A
1.0A
0.75A
0.64A
0.375A
CURRENT RANGE
0.3 ~ 2.72A 0.3 ~ 3.0A 0.3 ~ 2.0A 0.2 ~2.0A 0.15 ~ 1.50A 0.1 ~ 1.20A 0.1 ~ 1.0A 0.1 ~ 0.75A 0.06 ~ 0.64A 0.05 ~ 0.375A
RATED POWER (max.)
9W
15W
15W
18W
18W
18W
18W
18W
18W
18W
OUTPUT
RIPPLE & NOISE (max.) Note.3 50mVp-p 50mVp-p 80mVp-p
VOLTAGE ADJ. RANGE
Fixed
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
5.0%
LINE REGULATION Note.5 1.0%
1.0%
1.0%
LOAD REGULATION Note.6 5.0%
5.0%
5.0%
SETUP, RISE, HOLD UP TIME 300ms, 100ms, 16ms at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
80mVp-p
5.0%
1.0%
5.0%
80mVp-p
3.0%
1.0%
3.0%
100mVp-p 150mVp-p 180mVp-p 240mVp-p 240mVp-p
3.0%
3.0%
2.0%
2.0%
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
3.0%
3.0%
2.0%
2.0%
2.0%
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT
55%
70%
72%
72%
74%
77%
78%
80%
81%
82%
0.5A / 100VAC
INRUSH CURRENT (max.) 40A / 230VAC
LEAKAGE CURRENT(max.) 0.25mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
110 ~ 200% rated output power
130 ~ 350% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Clamp by zener diode, output short
WORKING TEMP.
0 ~ +50 (Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943 Approved
SAFETY &
EMC
(Note. 7)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254 class B
Compliance to EN61000-3-2,3, GB17625.1
EMS IMMUNITY
MTBF
OTHERS DIMENSION
PACKING
PLUG
CONNECTOR CABLE
Compliance to EN61000-4-2,3,4,5,6,8,11, Light industry level, criteria A
500Khrs min. MIL-HDBK-217F(25 )
79*54*33mm (L*W*H)
220g ; 60pcs / 13.5kg / CARTON
Standard type P1J: 2.1 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
Standard type UL1185 6ft (with ferrite core) for stock ; Other type available by customer requested
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:ES18B-SPEC 2007-03-01