English
Language : 

ES18A Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 9~18WAC-DC Single Output Desktop
9~18W AC-DC Single Output Desktop
ES18A series
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Class power ( with earth pin)
Full output 3~48V safety approval
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
RCC control circuit and regulated
LED indicator for power on
Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE
1 year warranty
SPECIFICATION
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
ES18A03-P1J ES18A05-P1J ES18A07-P1J ES18A09-P1J ES18A12-P1J ES18A15-P1J ES18A18-P1J ES18A24-P1J ES18A28-P1J ES18A48-P1J
SAFETY MODEL NO.
ES18A03 ES18A05 ES18A07 ES18A09 ES18A12 ES18A15 ES18A18 ES18A24 ES18A28 ES18A48
DC VOLTAGE
Note.2 3.3V
5V
7.5V
9V
12V
15V
18V
24V
28V
48V
RATED CURRENT
2.72A
3.0A
2.0A
2.0A
1.50A
1.20A
1.0A
0.75A
0.64A
0.375A
CURRENT RANGE
0.3 ~ 2.72A 0.3 ~ 3.0A 0.3 ~ 2.0A 0.2 ~2.0A 0.15 ~ 1.50A 0.1 ~ 1.20A 0.1 ~ 1.0A 0.1 ~ 0.75A 0.06 ~ 0.64A 0.05 ~ 0.375A
OUTPUT
RATED POWER (max.)
9W
15W
15W
RIPPLE & NOISE (max.) Note.3 50mVp-p 50mVp-p 80mVp-p
VOLTAGE ADJ. RANGE
Fixed
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
5.0%
LINE REGULATION Note.5 1.0%
1.0%
1.0%
LOAD REGULATION Note.6 5.0%
5.0%
5.0%
SETUP, RISE, HOLD UP TIME 300ms, 100ms, 16ms at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
18W
80mVp-p
5.0%
1.0%
5.0%
18W
80mVp-p
3.0%
1.0%
3.0%
18W
18W
18W
18W
18W
100mVp-p 150mVp-p 180mVp-p 240mVp-p 240mVp-p
3.0%
3.0%
2.0%
2.0%
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
3.0%
3.0%
2.0%
2.0%
2.0%
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT
55%
70%
72%
72%
74%
77%
78%
80%
81%
82%
0.5A / 100VAC
INRUSH CURRENT (max.) 40A / 230VAC
LEAKAGE CURRENT(max.) 0.75mA / 240VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
110 ~ 200% rated output power
130 ~ 350% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Clamp by zener diode, output short
WORKING TEMP.
0 ~ +50 (Refer to output load derating curve)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943 Approved
SAFETY &
EMC
(Note. 7)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC , I/P-FG:1.5KVAC
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254 class B
Compliance to EN61000-3-2,3, GB17625.1
EMS IMMUNITY
MTBF
OTHERS DIMENSION
PACKING
PLUG
CONNECTOR CABLE
Compliance to EN61000-4-2,3,4,5,6,8,11, Light industry level, criteria A
500Khrs min. MIL-HDBK-217F(25 )
93*54*36mm (L*W*H)
250g ; 60pcs / 15kg / CARTON
Standard type P1J: 2.1 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
Standard type UL1185 6ft (with ferrite core) for stock ; Other type available by customer requested
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:ES18A-SPEC 2007-03-01