English
Language : 

EPS-25 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 25W Single Output Switching Power Supply
25W Single Output Switching Power Supply
EPS-25 series
Features :
Universal AC input / Full range
High efficiency up to 90%
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
3" 2" compact size
LED indicator for power on
No load power consumption<0.3W
3 years warranty
SPECIFICATION
MODEL
EPS-25-3.3 EPS-25-5 EPS-25-7.5 EPS-25-12 EPS-25-15 EPS-25-24 EPS-25-27 EPS-25-36 EPS-25-48
DC VOLTAGE
3.3V
5V
7.5V
12V
15V
24V
27V
36V
48V
RATED CURRENT
5A
5A
3.4A
2.1A
1.7A
1.05A
0.95A
0.7A
0.53A
CURRENT RANGE
0 ~ 5.5A 0 ~ 5.5A 0 ~ 3.74A 0 ~ 2.34A 0 ~ 1.87A 0 ~ 1.17A 0 ~ 1.05A 0 ~ 0.78A 0 ~ 0.59A
RATED POWER
16.5W
25W
25.5W
25.2W
25.5W
25.2W
25.65W
25.2W
25.44W
PEAK LOAD(10sec.) Note.6 18.15W
27.5W
28.05W
28.08W
28.05W
28.08W
28.35W
28.08W
28.32W
OUTPUT
RIPPLE & NOISE (max.) Note.2 60mVp-p
VOLTAGE ADJ. RANGE
3.1 ~ 3.6V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
LOAD REGULATION
1.0%
60mVp-p
4.75 ~ 5.5V
2.0%
0.5%
1.0%
80mVp-p 100mVp-p 100mVp-p 180mVp-p
7.13 ~ 8.25V 10.8 ~ 13.5V 13.5 ~ 16.5V 21.6 ~ 27V
2.0%
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
1.0%
0.5%
0.5%
0.5%
180mVp-p 200mVp-p
24.3 ~ 29.7V 32.4 ~ 39.6V
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
240mVp-p
43.2 ~ 52.8V
1.0%
0.5%
0.5%
SETUP, RISE TIME
1000ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
50ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
79%
81%
83%
86%
87%
88%
89%
89%
90%
0.6A/115VAC 0.4A/230VAC
INRUSH CURRENT (Typ.) COLD START 35A/230VAC
LEAKAGE CURRENT
<1mA/240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
115 ~ 170% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.7 ~ 4.6V 5.6 ~ 6.75V 8.63~ 10.5V 14 ~ 17V 17.25 ~ 20.25V 27.6 ~ 32.4V 31.05 ~ 36.45V 39.7 ~ 46.8V 53.3 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY &
EMC
(Note 4)
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, heavy industry level, criteria A
655.3Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
76.2*50.8*24mm (L*W*H)
PACKING
0.081Kg; 120pcs/10.7Kg/0.97CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltage. Please check the static characteristics for more details.
6. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
File Name:EPS-25-SPEC 2012-04-20