English
Language : 

ELP-75 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 75W Single Output with PFC Function
75W Single Output with PFC Function
ELP-75 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
High efficiency up to 90%
Optional L-Bracket and cover (ELP-75-x-C, x=3.3,5,12,15,24,36,48)
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
1U low profile
LED indicator for power on
No load power consumption<0.5W
3 years warranty
SPECIFICATION
MODEL
ELP-75-3.3
ELP-75-5
ELP-75-12
ELP-75-15
ELP-75-24
ELP-75-36
ELP-75-48
DC VOLTAGE
3.3V
5V
12V
15V
24V
36V
48V
RATED CURRENT
15A
15A
6.25A
5A
3.15A
2.1A
1.6A
CURRENT RANGE
0 ~ 15A
0 ~ 15A
0 ~ 6.25A
0 ~ 5A
0 ~ 3.15A
0 ~ 2.1A
0 ~ 1.6A
RATED POWER
49.5W
75W
75W
75W
75.6W
75.6W
76.8W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
120mVp-p
150mVp-p
240mVp-p
280mVp-p
300mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
3 ~ 3.6V
VOLTAGE TOLERANCE Note.3 3.0%
LINE REGULATION
0.5%
LOAD REGULATION
2.0%
4.75 ~ 5.5V
2.0%
0.5%
1.5%
10.8 ~ 13.2V
2.0%
0.5%
1.0%
13.5 ~ 16.5V
2.0%
0.5%
1.0%
21.6 ~ 26.4V
1.0%
0.5%
1.0%
32.4 ~ 39.6V
1.0%
0.5%
1.0%
43.2 ~ 52.8V
1.0%
0.5%
1.0%
SETUP, RISE TIME
2500ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
20ms/230VAC 20ms/115VAC at full load
VOLTAGE RANGE
Note.6 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.) Note.5 3.3V: PF>0.91/230VAC 5V~48V: PF>0.95/230VAC PF>0.98/115VAC at full load
INPUT
EFFICIENCY (Typ.)
80%
82%
89%
90%
90%
90%
90%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.8A/115VAC 1 A/230VAC
COLD START 60A/230VAC
LEAKAGE CURRENT
<1mA/240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.7 ~ 4.45V
5.6 ~ 6.75V
13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
39.7 ~ 46.8V
53.3 ~ 64.8V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY &
EMC
(Note 4)
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, heavy industry level, criteria A
MTBF
345.3Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
PCB:175*60*27mm (L*W*H) with optional CASE:195*68.5*33mm (L*W*H)
PACKING
PCB:0.25Kg; 48pcs/13Kg/0.85CUFT with optional CASE:0.54Kg; 25pcs/14.5Kg/0.59CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. 3.3V PF>0.92/230VAC, others PF>0.95/230VAC.
6. Derating may be needed under low input voltage. Please check the derating curve for more details.
File Name:ELP-75-SPEC 2011-05-09