English
Language : 

ELN-60_11 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 60W Single Output Class 2 Switching Power Supply
60W Single Output Class 2 Switching Power Supply
ELN-60 series
Features :
Universal AC input / Full range
Protections: Short circuit / Over current / Over voltage
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Optional dimming function : 1~10VDC (D type) or PWM (P type) controlled
Fully isolated plastic case with IP64 level
Class power unit, no FG
Pass LPS
Suitable for LED lighting and moving sign applications (Note.9)
100% full load burn-in test
Low cost, high reliability
2 years warranty
SPECIFICATION
LPS IP64
( for 48V only)
( except for 48V )
MODEL
ELN-60-9
ELN-60-12
ELN-60-15
ELN-60-24
ELN-60-27
ELN-60-48
OUTPUT
DC VOLTAGE
9V
12V
15V
LED OPERATION VOLTAGE Note.8 3 ~ 9V
6 ~ 12V
7.5 ~ 15V
RATED CURRENT
5A
5A
4A
CURRENT RANGE
0 ~ 5A
0 ~ 5A
0 ~ 4A
RATED POWER
45W
60W
60W
RIPPLE & NOISE (max.) Note.2 120mVp-p
120mVp-p
150mVp-p
8.7 ~ 10.5V
10.8 ~ 13.2V
13.5 ~ 16.5V
VOLTAGE ADJ. RANGE Note.7
Can be adjusted by internal potentiometer SVR1
CURRENT ADJ. RANGE Note.7 -25% ~ 3%. Can be adjusted by internal potentiometer SVR2
VOLTAGE TOLERANCE Note.3 5.0%
LINE REGULATION
1.0%
LOAD REGULATION
2.0%
SETUP, RISE TIME Note.6 500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load
HOLD UP TIME (Typ.)
50ms/230VAC 16ms/115VAC at full load
24V
12 ~ 24V
2.5A
0 ~ 2.5A
60W
150mVp-p
21.6 ~ 26.4V
27V
13.5 ~ 27V
2.3A
0 ~ 2.3A
62.1W
200mVp-p
24.3 ~ 29.7V
48V
24 ~ 48V
1.3A
0 ~ 1.3A
62.5W
250mVp-p
43.2 ~ 52.8V
VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
82%
85%
86%
87%
87%
88%
INPUT
AC CURRENT (Typ.)
1.2A/115VAC 0.7A/230VAC
INRUSH CURRENT (max.) COLD START 60A/230VAC
LEAKAGE CURRENT
0.25mA / 240VAC
OVER CURRENT
PROTECTION
OVER VOLTAGE
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
11 ~ 13.5V
13.8 ~ 16V
17.5 ~ 21V
28 ~ 32V
31 ~ 35V
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION DIMMING CONTROL (OPTIONAL) 1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz
54 ~ 60V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMC EMISSION
-20 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1310 Class 2, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1, EN61347-2-13
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
OTHERS
NOTE
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
MTBF
603Khrs min. MIL-HDBK-217F (25 )
DIMENSION
181*61.5*35mm (L*W*H)
PACKING
0.4Kg; 24pcs/11Kg/0.75CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
8. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications.
9. In the European market this product is only suitable for LED lighting applications that don't have to comply with the harmonic current requirements of
EN61000-3-2 Class C.
File Name:ELN-60-SPEC 2011-07-28