English
Language : 

ELN-60 Datasheet, PDF (1/4 Pages) Mean Well Enterprises Co., Ltd. – 60W Single Output Class 2 Switching Power Supply
60W Single Output Class 2 Switching Power Supply
ELN-60 series
SPECIFICATION
Features :
Universal AC input / Full range
Built-in constant current limiting circuit with adjustable OCP level
Protections: Short circuit / Overload / Over voltage
Fully isolated plastic case with IP64 level
IP64 design for indoor or outdoor installations
Optional dimming function : 1~10VDC(D type) or PWM controlled(P type)
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
Low cost, high reliability
Suitable for LED lighting and moving sign applications
2 years warranty
IP64
MODEL
ELN-60-9
ELN-60-12
ELN-60-15
ELN-60-24
ELN-60-27
ELN-60-48
OUTPUT
DC VOLTAGE
9V
12V
15V
LED OPERATION VOLTAGE Note.8 3 ~ 9V
3 ~ 12V
3 ~ 15V
RATED CURRENT
5A
5A
4A
CURRENT RANGE
0 ~ 5A
0 ~ 5A
0 ~ 4A
RATED POWER
45W
60W
60W
RIPPLE & NOISE (max.) Note.2 120mVp-p
120mVp-p
150mVp-p
8.7 ~ 10.5V
10.8 ~ 13.2V
13.5 ~ 16.5V
VOLTAGE ADJ. RANGE Note.7
Can be adjusted by internal potential meter SVR1
CURRENT ADJ. RANGE Note.7 -25% ~ 3%. Can be adjusted by internal potential meter SVR2
VOLTAGE TOLERANCE Note.3 5.0%
LINE REGULATION
1.0%
LOAD REGULATION
2.0%
SETUP, RISE TIME Note.6 500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load
HOLD UP TIME (Typ.)
50ms/230VAC 16ms/115VAC at full load
24V
3 ~ 24V
2.5A
0 ~ 2.5A
60W
150mVp-p
21.6 ~ 26.4V
27V
3 ~ 27V
2.3A
0 ~ 2.3A
62.1W
200mVp-p
24.3 ~ 29.7V
48V
3 ~ 48V
1.3A
0 ~ 1.3A
62.5W
250mVp-p
43.2 ~ 52.8V
VOLTAGE RANGE Note.5 90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
82%
85%
86%
87%
87%
88%
INPUT
AC CURRENT (Typ.)
1.2A/115VAC 0.7A/230VAC
INRUSH CURRENT(max.) COLD STAR 60A/230VAC
LEAKAGE CURRENT
0.25mA / 240VAC
OVER CURRENT
PROTECTION
OVER VOLTAGE
95 ~ 110%
130% max.
Protection type : Constant current limiting, recovers automatically after fault condition is removed
11 ~ 13.5V
13.8 ~ 16V
17.5 ~ 21V
28 ~ 32V
31 ~ 35V
Protection type : Shut down o/p voltage, re-power on to recover
54 ~ 60V
FUNCTION DIMMING CONTROL (OPTIONAL) 1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz
WORKING TEMP.
-20 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
Design refer to UL1310 Class 2,TUV EN60950-1, CAN/CSA C22.2 No. 223-M91(except for 48V), EN61347-2-13; IP64 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
EMC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
603Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
181*61.5*35mm (L*W*H)
PACKING
0.4Kg; 24pcs/11Kg/0.75CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the derating curve for more details.
5. The power supply is considered a component which will be installed a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
8. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications.
File Name:ELN-60-SPEC 2008-06-16