English
Language : 

ELN-60-48D Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 60W Single Output Class 2 Switching Power Supply
60W Single Output Class 2 Switching Power Supply
ELN-60 series
¡½ Features :
¡EUniversal AC input / Full range
¡EProtections: Short circuit / Over current / Over voltage
¡ECooling by free air convection
¡EBuilt-in constant current limiting circuit with adjustable OCP level
¡EOptional dimming function : 1~10VDC (D type) or PWM (P type) controlled
¡EFully isolated plastic case with IP64 level
¡E ¢º Class power unit, no FG
¡EClass 2 power unit
¡EPass LPS
¡ESuitable for LED lighting and moving sign applications (Note.9)
¡E100% full load burn-in test
¡ELow cost, high reliability
¡E2 years warranty
SPECIFICATION
LPS IP64
( for 48V only)
( except for 48V )
MODEL
ELN-60-9
ELN-60-12
ELN-60-15
ELN-60-24
ELN-60-27
ELN-60-48
OUTPUT
INPUT
DC VOLTAGE
9V
12V
15V
24V
LED OPERATION VOLTAGE Note.8 3 ~ 9V
6 ~ 12V
7.5 ~ 15V
12 ~ 24V
RATED CURRENT
5A
5A
4A
2.5A
CURRENT RANGE
0 ~ 5A
0 ~ 5A
0 ~ 4A
0 ~ 2.5A
RATED POWER
45W
60W
60W
60W
RIPPLE & NOISE (max.) Note.2 120mVp-p
120mVp-p
150mVp-p
150mVp-p
8.7 ~ 10.5V
10.8 ~ 13.2V
13.5 ~ 16.5V
VOLTAGE ADJ. RANGE Note.7
Can be adjusted by internal potentiometer SVR1
21.6 ~ 26.4V
CURRENT ADJ. RANGE Note.7 -25% ~ 3%. Can be adjusted by internal potentiometer SVR2
¡Ó VOLTAGE TOLERANCE Note.3 5.0%
LINE REGULATION
¡Ó1.0%
LOAD REGULATION
¡Ó2.0%
SETUP, RISE TIME Note.6 500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load
HOLD UP TIME (Typ.)
50ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
82%
85%
86%
87%
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
1.2A/115VAC 0.7A/230VAC
£g COLD START 60A(twidth=600 s measured at 50% Ipeak) at 230VAC
LEAKAGE CURRENT
0.25mA / 240VAC
27V
13.5 ~ 27V
2.3A
0 ~ 2.3A
62.1W
200mVp-p
24.3 ~ 29.7V
87%
48V
24 ~ 48V
1.3A
0 ~ 1.3A
62.5W
250mVp-p
43.2 ~ 52.8V
88%
OVER CURRENT
PROTECTION
OVER VOLTAGE
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
11 ~ 13.5V
13.8 ~ 16V
17.5 ~ 21V
28 ~ 32V
31 ~ 37V
Protection type : Shut down o/p voltage, re-power on to recover
54 ~ 60V
FUNCTION DIMMING CONTROL (OPTIONAL) 1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz
WORKING TEMP.
¢J -20 ~ +60 (Refer to "Derating Curve")
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
20 ~ 90% RH non-condensing
¢J -40 ~ +80 , 10 ~ 95% RH
¡Ó ¢J ¢J 0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1310, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1
WITHSTAND VOLTAGE
SAFETY &
EMC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3KVAC
¢J I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
¢J 603K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
181*61.5*35mm (L*W*H)
NOTE
PACKING
0.4Kg; 24pcs/11Kg/0.75CUFT
¢J 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
8. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications.
9. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
File Name:ELN-60-SPEC 2012-12-26