English
Language : 

ELN-30_12 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 30W Single Output Switching Power Supply
30W Single Output Switching Power Supply
ELN-30 series
Features :
Universal AC input / Full range
Protections: Short circuit / Over current / Over voltage
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Optional dimming function : 1.1~10VDC (D type) or PWM (P type) controlled
Fully isolated plastic case with IP64 level
Class power unit, no FG
Class 2 power unit
Pass LPS
Suitable for LED lighting and moving sign applications (Note.8)
100% full load burn-in test
Low cost
2 years warranty
SPECIFICATION
LPS IP64
( for 48V only)
( except for 48V )
MODEL
ELN-30-5
ELN-30-9
ELN-30-12
ELN-30-15
ELN-30-24
ELN-30-27
ELN-30-48
OUTPUT
INPUT
DC VOLTAGE
5V
9V
12V
15V
LED OPERATION VOLTAGE Note.7 3 ~ 5V
3 ~ 9V
3 ~ 12V
3 ~ 15V
RATED CURRENT
5A
3.4A
2.5A
2A
CURRENT RANGE
0 ~ 5A
0 ~ 3.4A
0 ~ 2.5A
0 ~ 2A
RATED POWER
25W
30.6W
30W
30W
RIPPLE & NOISE (max.) Note.2 80mVp-p
100mVp-p
120mVp-p
120mVp-p
VOLTAGE ADJ. RANGE
4.5 ~ 5.5V
8.7 ~ 10.5V
10.8 ~ 13.2V
Can be adjusted by internal potentiometer SVR1
13.5 ~ 16.5V
CURRENT ADJ. RANGE
-25% ~ 3%. Can be adjusted by internal potentiometer SVR2
VOLTAGE TOLERANCE Note.3 5.0%
LINE REGULATION
1.0%
LOAD REGULATION
2.0%
SETUP, RISE TIME Note.6 500ms, 80ms / 230VAC 1000ms, 80ms / 115VAC at full load
HOLD UP TIME (Typ.)
50ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
75%
80%
82%
82%
AC CURRENT (Typ.)
0.75A/115VAC 0.48A/230VAC
INRUSH CURRENT (max.) COLD START 60A/230VAC
LEAKAGE CURRENT
0.25mA / 240VAC
24V
3 ~ 24V
1.25A
0 ~ 1.25A
30W
150mVp-p
21.6 ~ 26.4V
85%
27V
3 ~ 27V
1.12A
0 ~ 1.12A
30.24W
150mVp-p
24.3 ~ 29.7V
85%
48V
3 ~ 48V
0.63A
0 ~ 0.63A
30.24W
250mVp-p
43.2 ~ 52.8V
87%
OVER CURRENT
PROTECTION
OVER VOLTAGE
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V 11 ~ 13.5V
13.8 ~ 16V
17.5 ~ 21V
28 ~ 32V
31 ~ 36.4V
Protection type : Shut down o/p voltage, re-power on to recover
54 ~ 60V
FUNCTION DIMMING CONTROL (OPTIONAL) 1.1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz
WORKING TEMP.
-20 ~ +60 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1310, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1
WITHSTAND VOLTAGE
SAFETY &
EMC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
MTBF
628.3Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
145*47*30mm (L*W*H)
PACKING
0.26Kg; 60pcs/16.6Kg/1.25CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications.
8. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
File Name:ELN-30-SPEC 2012-03-20