English
Language : 

ELN-30 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 30W Single Output Switching Power Supply
30W Single Output Switching Power Supply
ELN-30 series
Features :
Universal AC input / Full range
Fully isolated plastic case with IP64 level
Built-in constant current limiting circuit with adjustable OCP level
Protections: Short circuit / Overload / Over voltage
Optional dimming function : 1.1~10VDC (D type) or PWM (P type) controlled
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
Suitable for LED lighting and moving sign applications
Low cost
2 years warranty
SPECIFICATION
IP64
MODEL
ELN-30-5
ELN-30-9
ELN-30-12
ELN-30-15
ELN-30-24
ELN-30-27
ELN-30-48
DC VOLTAGE
5V
9V
12V
15V
24V
27V
48V
LED OPERATION VOLTAGE Note.7 3 ~ 5V
3 ~ 9V
3 ~ 12V
3 ~ 15V
3 ~ 24V
3 ~ 27V
3 ~ 48V
RATED CURRENT
5A
3.4A
2.5A
2A
1.25A
1.12A
0.63A
CURRENT RANGE
0 ~ 5A
0 ~ 3.4A
0 ~ 2.5A
0 ~ 2A
0 ~ 1.25A
0 ~ 1.12A
0 ~ 0.63A
OUTPUT
RATED POWER
25W
30.6W
30W
RIPPLE & NOISE (max.) Note.2 80mVp-p
100mVp-p
120mVp-p
VOLTAGE ADJ. RANGE
4.5 ~ 5.5V
8.7 ~ 10.5V
10.8 ~ 13.2V
Can be adjusted by internal potential meter SVR1
30W
120mVp-p
13.5 ~ 16.5V
30W
150mVp-p
21.6 ~ 26.4V
30.24W
150mVp-p
24.3 ~ 29.7V
30.24W
250mVp-p
43.2 ~ 52.8V
CURRENT ADJ. RANGE
-25% ~ 3%. Can be adjusted by internal potential meter SVR2
VOLTAGE TOLERANCE Note.3 5.0%
LINE REGULATION
1.0%
LOAD REGULATION
2.0%
SETUP, RISE TIME Note.6 500ms, 80ms / 230VAC 1000ms, 80ms / 115VAC at full load
HOLD UP TIME (Typ.)
50ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
75%
80%
82%
82%
85%
85%
87%
INPUT
AC CURRENT
0.75A/115VAC 0.48A/230VAC
INRUSH CURRENT(max.) COLD STAR 60A/230VAC
LEAKAGE CURRENT
0.25mA / 240VAC
OVER CURRENT
PROTECTION
OVER VOLTAGE
95 ~ 110%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V 11 ~ 13.5V
13.8 ~ 16V
17.5 ~ 21V
28 ~ 32V
31 ~ 36.4V
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION DIMMING CONTROL (OPTIONAL) 1 ~ 10VDC or PWM
54 ~ 60V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
SAFETY STANDARDS
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Design refer to UL1310 Class 2,TUV EN60950-1, CAN/CSA C22.2 No. 223-M91(except for 48V), EN61347-2-13; IP64 approved
SAFETY &
EMC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
628.3Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
145*47*30mm (L*W*H)
PACKING
0.26Kg; 60pcs/16.6Kg/1.25CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the derating curve for more details.
5. The power supply is considered a component which will be installed a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications.
File Name:ELN-30-SPEC 2008-06-16