DR-UPS40_10 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 40A DC UPS Module
40A DC UPS Module
DR-UPS40
Features :
Battery controller for DIN Rail UPS system
Parallel connection to DC BUS
Suitable for 24V system up to 40A
Installed on DIN Rail TS35 / 7.5 or 15
Built-in battery test function
Battery polarity protection
Relay contact signal output and LED indicator for DC BUS OK,
Battery Fail, and Battery Discharge
Cooling by free air convection
3 years warranty
SPECIFICATION
MODEL
DR-UPS40
DC INPUT / DC VOLTAGE (Typ.)
DC BUS RATED CURRENT
24 ~ 29V
40A
BATTERY
INPUT /
OUTPUT
VOLTAGE RANGE (Typ.)
21 ~ 29V
CURRENT RANGE
0 ~ 40A
CHARGE CURRENT (Typ.) 2A
EXTERNAL BATTERY (Typ.) 4 / 7 / 12AH / 24V
RELAY CONTACT RATING (max.) 30VDC, 1A
DC BUS OK
Relay contact : Short when DC voltage between 21~29V( 3%), relay contacts
LED(Green) : DC BUS OK : light ; DC BUS fail : dark
FUNCTION BATTERY FAIL
Relay contact : Short when battery failure is observed through the battery test function, relay contacts
Note.2
LED(Red) : Battery over-discharge warning or battery broken : light ; Battery OK : dark
BATTERY DISCHARGE
Relay contact : Short when battery in discharge condition, relay contacts
LED(Yellow) : Battery discharging : light ; Battery is not discharging or discharging current<2.0A : dark
WORKING TEMP.
-20 ~ +70
WORKING HUMIDITY
20 ~ 90% RH
ENVIRONMENT
STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
VIBRATION
Component : 10 ~ 500Hz, 2G 10min./1cycle, 60min. each X, Y, Z axes ; Mounting : Compliance to IEC600068-2-6
SAFETY &
EMC
(Note 3)
OTHERS
NOTE
WITHSTAND VOLTAGE
Terminal-Chassis :0.5KVAC, Relay Contacts-Terminal :0.5KVAC
ISOLATION RESISTANCE Terminal-Chassis :>100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, heavy industry level, criteria A
MTBF
161.9Khrs min. MIL-HDBK-217F (25 )
DIMENSION
55.5*125.2*100mm (W*H*D)
PACKING
0.55Kg; 20pcs/12Kg/1.29CUFT
1. All parameters NOT specially mentioned are measured at rated load and 25 of ambient temperature.
2. Every 25 seconds, unit will send out test signal through "Battery Fail" relay contact and LED indicator once the battery is fail.
3. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:DR-UPS40-SPEC 2010-10-18