English
Language : 

DR-100 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 100W Single Output Industrial DIN Rail Power Supply
100W Single Output Industrial DIN Rail Power Supply
DR-100 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Isolation class
LED indicator for power on
No load power consumption<1W
100% full load burn-in test
3 years warranty
..
SPECIFICATION
MODEL
DR-100-12
DR-100-15
DR-100-24
DC VOLTAGE
12V
15V
24V
RATED CURRENT
7.5A
6.5A
4.2A
CURRENT RANGE
0 ~ 7.5A
0 ~ 6.5A
0 ~ 4.2A
RATED POWER
90W
97.5W
100.8W
RIPPLE & NOISE (max.) Note.2 120mVp-p
OUTPUT VOLTAGE ADJ. RANGE
12 ~ 15V
120mVp-p
15 ~ 18V
150mVp-p
24 ~ 29V
VOLTAGE TOLERANCE Note.3 2.0%
1.0%
1.0%
LINE REGULATION
1.0%
1.0%
1.0%
LOAD REGULATION
1.0%
1.0%
1.0%
SETUP, RISE TIME
2700ms, 80ms/230VAC 2700ms, 80ms/115VAC at full load
HOLD UP TIME (Typ.)
50ms/230VAC 18ms/115VAC at full load
VOLTAGE RANGE
88 ~ 264VAC 124 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT EFFICIENCY (Typ.)
87%
87%
89%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
3A/115VAC 1.6A/230VAC
COLD START 30A/115VAC 45A/230VAC
OVERLOAD
PROTECTION OVER VOLTAGE
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
16 ~ 20V
19 ~ 23V
30 ~ 35V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
90 15 (RTH2) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-20 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved, design refer to EN50178
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
ISOLATION RESISTANCE I/P-O/P:>100M Ohms/500VDC 25 70%RH
EMI CONDUCTION & RADIATION Compliance to EN61204-3, EN55022 ClassB
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
MTBF
486K hrs min. MIL-HDBK-217F (25 )
DIMENSION
100*93*56mm (W*H*D)
PACKING
0.35Kg; 36pcs/13.6Kg/0.89CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Harmonic current test @ 90% load.
File Name:DR-100-SPEC 2007-08-09