English
Language : 

CLG-60_11 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 60W Single Output LED Power Supply
60W Single Output LED Power Supply
CLG-60 series
Features :
Universal AC input / Full range (up to 295VAC)
Built-in active PFC function
High efficiency 89%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
IP67 design for indoor or outdoor installations
UL1310 Class 2 power unit
Pass LPS
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications (Note.2)
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
LPS F 110 M M SELV
( for 48V only)
IP67 ( except for 48V )
( for 20~27V only)
SPECIFICATION
MODEL
CLG-60-12
CLG-60-15
CLG-60-20
CLG-60-24
CLG-60-27
CLG-60-36
CLG-60-48
OUTPUT
INPUT
DC VOLTAGE
12V
15V
20V
24V
27V
36V
48V
CONSTANT CURRENT REGION Note.5 8.4 ~ 12V
10.5 ~ 15V
14 ~ 20V
16.8 ~ 24V
18.9 ~ 27V
25.2 ~ 36V
33.6 ~ 48V
RATED CURRENT
5A
4A
3A
2.5A
2.3A
1.7A
1.3A
CURRENT RANGE
0 ~ 5A
0 ~ 4A
0 ~ 3A
0 ~ 2.5A
0 ~ 2.3A
0 ~ 1.7A
0 ~ 1.3A
RATED POWER
60W
60W
60W
60W
62.1W
61W
62.5W
RIPPLE & NOISE (max.) Note.2 2Vp-p
2.4Vp-p
1.8Vp-p
2.7Vp-p
2.7Vp-p
3.6Vp-p
4.6Vp-p
VOLTAGE ADJ. RANGE
11.5 ~ 13V
14.5 ~ 16.2V 19.5 ~ 22V
Fixed can be modified between the range above
24 ~ 26V
25 ~ 30V
32.5 ~ 39V
43.6 ~ 51.8V
CURRENT ADJ. RANGE
Fixed. Can be modified between 3% ~ -25% rated output current
VOLTAGE TOLERANCE Note.3 10%
LINE REGULATION
3.0%
LOAD REGULATION
5.0%
SETUP TIME
3000ms / 230VAC 5000ms / 115VAC at full load
VOLTAGE RANGE Note.4 90 ~ 295VAC 127 ~ 417VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.94/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
85%
86%
87.5%
87%
88%
89%
89%
AC CURRENT (Typ.)
0.8A/115VAC 0.4A/230VAC
INRUSH CURRENT(max.) 40A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER CURRENT
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
OVER VOLTAGE
PROTECTION
Hiccup mode, recovers automatically after fault condition is removed
13.8 ~ 16V
17.5 ~ 21V
23 ~ 26V
28 ~ 32V
Protection type : Shut down o/p voltage, re-power on to recover
31 ~ 35V
41 ~ 46V
54 ~ 60V
12V: 90 10 (TSW1) detect on heatsink of power transistor
OVER TEMPERATURE
15V ~ 48V: 85 10 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL879, UL8750, UL1310 Class 2, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V) ;
J61347-1, J61347-2-13(20~27only), IP67 approved
SAFETY & WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
EMC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), criteria A
MTBF
495.7Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
195.6*61.5*38.8mm (L*W*H)
PACKING
0.86Kg; 16pcs/14.8Kg/0.54CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:CLG-60-SPEC 2011-07-28