English
Language : 

CLG-60 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 60W Single Output Switching Power Supply
60W Single Output Switching Power Supply
CLG-60 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
IP67 design for indoor or outdoor installations
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
3 years warranty
SPECIFICATION
LPS F 110 M M SELV
EQUIVALENT
( for 48V only)
IP67 ( except for 48V )
MODEL
CLG-60-12
CLG-60-15
CLG-60-20
CLG-60-24
CLG-60-27
CLG-60-36
CLG-60-48
OUTPUT
DC VOLTAGE
12V
15V
20V
24V
CONSTANT CURRENT REGION Note.6 8.4 ~ 12V
10.5 ~ 15V
14 ~ 20V
16.8 ~ 24V
RATED CURRENT
5A
4A
3A
2.5A
CURRENT RANGE
0 ~ 5A
0 ~ 4A
0 ~ 3A
0 ~ 2.5A
RATED POWER
60W
60W
60W
60W
RIPPLE & NOISE (max.) Note.2 2Vp-p
2.4Vp-p
1.8Vp-p
2.7Vp-p
VOLTAGE ADJ. RANGE
11 ~ 13V
13.8 ~ 16.2V 18 ~ 22V
Fixed can be modified between the range above
22 ~ 26V
CURRENT ADJ. RANGE
Fixed can be modified between 3% ~ 25% rated output current
VOLTAGE TOLERANCE Note.3 10%
LINE REGULATION
4.0%
LOAD REGULATION
10%
SETUP, RISE TIME
1500ms, 100ms / 230VAC 3000ms, 100ms / 115VAC at full load
27V
18.9 ~ 27V
2.3A
0 ~ 2.3A
62.1W
2.7Vp-p
25 ~ 30V
36V
25.2 ~ 36V
1.7A
0 ~ 1.7A
61W
3.6Vp-p
32.5 ~ 39V
48V
33.6 ~ 48V
1.3A
0 ~ 1.3A
62.5W
4.6Vp-p
43.6 ~ 51.8V
VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF>0.9/230VAC PF>0.98/115VAC at full load
INPUT
EFFICIENCY(Typ.)
83%
84.5%
86.5%
86.5%
87%
87%
88%
AC CURRENT
0.8A/115VAC 0.4A/230VAC
INRUSH CURRENT(max.) 40A/230VAC
LEAKAGE CURRENT
0.5mA / 240VAC
OVER CURRENT
95 ~ 110%
130% (max)
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT Note.4 Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE
PROTECTION
13.8 ~ 16V
17.5 ~ 21V
22.8 ~ 25V
28 ~ 32V
Protection type : Shut down o/p voltage, re-power on to recover
31 ~ 35V
41 ~ 46V
12V: 90 10 (TSW1) detect on heatsink of power transistor
OVER TEMPERATURE
15V ~ 48V: 85 10 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
54 ~ 60V
WORKING TEMP.
-30 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1310 Class 2, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 approved
WITHSTAND VOLTAGE
I/P-O/P:4.25KVDC
SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMC
EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2 Class C (>50% load) ; EN61000-3-3
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61547, light industry level, criteria A
MTBF
495.7Khrs min. MIL-HDBK-217F (25 )
DIMENSION
172*61.5*39mm (L*W*H)
PACKING
0.86Kg; 16pcs/14.8Kg/0.54CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to OLP characteristics.
5. Derating may be needed under low input voltage. Please check the derating curve for more details.
6. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
File Name:CLG-60-SPEC 2008-08-18