English
Language : 

CLG-150_11 Datasheet, PDF (1/5 Pages) Mean Well Enterprises Co., Ltd. – 150W Single Output Switching Power Supply
150W Single Output Switching Power Supply
CLG-150 series
Features :
Universal AC input / Full range (up to 295VAC)
Built-in active PFC function
High efficiency 91%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP65 / IP67 design for indoor or outdoor installations
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
3 years warranty
F 110 SELV IP65 IP67
( for UL8750 48V only)
(option)
CLG-150-12 A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable.
C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal
potentiometer.
SPECIFICATION
MODEL
CLG-150-12 CLG-150-15 CLG-150-20 CLG-150-24 CLG-150-30 CLG-150-36 CLG-150-48
DC VOLTAGE
12V
15V
20V
24V
30V
36V
48V
CONSTANT CURRENT REGION Note.4 9 ~12V
RATED CURRENT
11A
11.25 ~ 15V
9.5A
15 ~ 20V
7.5A
18 ~ 24V
6.3A
22.5 ~ 30V
5A
27 ~ 36V
4.2A
36 ~ 48V
3.2A
RATED POWER
132W
142.5W
150W
151.2W
150W
151.2W
153.6W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
VOLTAGE ADJ. RANGE Note.6 9 ~ 13V
13 ~ 17V
17 ~ 22V
22 ~ 27V
26 ~ 32V
31 ~ 41V
40 ~ 56V
OUTPUT
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer or through output cable
5.5 ~ 11A
4.75 ~ 9.5A
3.75 ~ 7.5A
3.15 ~ 6.3A
VOLTAGE TOLERANCE Note.3 2.0%
2.0%
2.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
2.5 ~ 5A
1.0%
0.5%
2.1 ~ 4.2A
1.0%
0.5%
1.6 ~ 3.2A
1.0%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
3000ms, 80ms at full load 230VAC /115VAC
HOLD UP TIME (Typ.)
50ms / 230VAC 16ms / 115VAC at full load
VOLTAGE RANGE Note.5 90 ~ 295VAC 127 ~ 417VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
INPUT EFFICIENCY (Typ.)
88%
88%
90%
90%
91%
91%
91%
AC CURRENT (Typ.)
INRUSH CURRENT(max.)
2A / 115VAC 1A / 230VAC
COLD START 65A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVER CURRENT (Typ.) Note.4 95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
OVER VOLTAGE
13.5 ~ 16V
18 ~ 20V
23 ~ 27V
28 ~ 34V
33 ~ 36V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
42 ~ 48V
57 ~ 65V
OVER TEMPERATURE
100 10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, UL1012 ; EN61347-1, EN61347-2-13 independent (except for CLG-150 C type) ; UL60950-1, TUV EN60950-1 ;
SAFETY STANDARDS Note.7
J61347-1(option, except for CLG-150 C type), J61347-2-13, IP65 or IP67 approved
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
OTHERS
NOTE
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
MTBF
303.7Khrs min. MIL-HDBK-217F (25 )
DIMENSION
222.2*68*38.8mm (L*W*H)(CLG-150-Blank/A/B) 229*68*38.8mm (L*W*H)(CLG-150-C)
PACKING
1.0Kg; 12pcs/13Kg/0.58CUFT(CLG-150-Blank/A/B) 1Kg; 12pcs/13Kg/0.96CUFT(CLG-150-C)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A and type C only.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.