English
Language : 

CLG-100 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 100W Single Output Switching Power Supply
100W Single Output Switching Power Supply
CLG-100 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
IP67 design for indoor or outdoor installations
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
3 years warranty (Note.7)
SPECIFICATION
LPS F 110 M M SELV
EQUIVALENT
( for 48V only)
IP67 ( except for 48V )
MODEL
CLG-100-12 CLG-100-15 CLG-100-20 CLG-100-24 CLG-100-27 CLG-100-36 CLG-100-48
OUTPUT
DC VOLTAGE
12V
15V
20V
24V
CONSTANT CURRENT REGION Note.8 6 ~ 12V
7.5 ~ 15V
10 ~ 20V
12 ~ 24V
RATED CURRENT
Note.6 5A
5A
4.8A
4A
CURRENT RANGE Note.6 0 ~ 5A
0 ~ 5A
0 ~ 4.8A
0 ~ 4A
RATED POWER
Note.6 60W
75W
96W
96W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
Fixed. Can be modified between 0% ~ -15% rated output voltage
CURRENT ADJ. RANGE
Fixed. Can be modified between 3% ~ -25% rated output current
VOLTAGE TOLERANCE Note.3 3.0%
3.0%
3.0%
3.0%
LINE REGULATION
1.0%
LOAD REGULATION
2.0%
SETUP, RISE TIME
1200ms, 80ms / 230VAC 1200ms, 80ms / 115VAC at full load
HOLD UP TIME (Typ.)
60ms / 230VAC 30ms / 115VAC at full load
27V
13.5 ~ 27V
3.55A
0 ~ 3.55A
95.85W
150mVp-p
3.0%
36V
18 ~ 36V
2.65A
0 ~ 2.65A
95.4W
150mVp-p
2.0%
48V
24 ~ 48V
2A
0 ~ 2A
96W
200mVp-p
2.0%
INPUT
VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF>0.95/230VAC PF>0.95/115VAC at full load
EFFICIENCY (Typ.)
83%
85%
87%
87%
87%
87%
AC CURRENT
12V:0.8A/115VAC 0.4A/230VAC 15V:0.9A/115VAC 0.45A/230VAC 20V ~ 48V:1.1A/115VAC
INRUSH CURRENT(max.) COLD START 40A/230VAC
87%
0.55A/230VAC
LEAKAGE CURRENT
0.5mA / 240VAC
OVER CURRENT
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
95 ~ 100%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Note.4 Hiccup mode, recovers automatically after fault condition is removed
13 ~ 16V
16.5 ~ 20V
22 ~ 27V
27 ~ 34V
29 ~ 36V
39 ~ 48V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
52 ~ 64V
OVER TEMPERATURE
90 10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-30 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY &
EMC
SAFETY STANDARDS
UL1310 Class 2, UL879 ( listed in UL Sign Components Manual (SAM) ), TUV EN60950-1, EN61347-1, EN61347-2-13
CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2 Class C (>50% load) ; EN61000-3-3
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level (surge 4KV), criteria A
MTBF
301Khrs min. MIL-HDBK-217F (25 )
DIMENSION
222*68*39mm (L*W*H)
PACKING
1.0Kg; 12pcs/13Kg/0.49CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to OLP characteristics.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
7. 3 years warranty is guaranteed for operating ambient temperature no higher than 68 .
8. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
File Name:CLG-100-SPEC 2008-12-10