English
Language : 

CEN-60_12 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – CEN-60_12
60W Single Output LED Power Supply
CEN-60 series
½ Features :
Universal AC input / Full range (up to 295VAC)
Protections: Short circuit / Over current / Over voltage / Over temperature
Output voltage and constant current level adjustable
Built-in active PFC function
IP66 design for indoor or outdoor installations
Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
SPECIFICATION
F 110 M M SELV IP66
MODEL
CEN-60-12 CEN-60-15 CEN-60-20 CEN-60-24 CEN-60-30 CEN-60-36 CEN-60-42 CEN-60-48 CEN-60-54
DC VOLTAGE
12V
CONSTANT CURRENT OPERATION VOLTAGE Note.5 9 ~ 12V
RATED CURRENT
5A
15V
20V
11.25 ~ 15V 15 ~ 20V
4A
3A
24V
18 ~ 24V
2.5A
30V
22.5 ~ 30V
2A
36V
27 ~ 36V
1.7A
42V
31.5 ~ 42V
1.45A
48V
36 ~ 48V
1.3A
54V
40.5 ~ 54V
1.15A
OUTPUT
CURRENT RANGE
0 ~ 5A
0 ~ 4A
0 ~ 3A
0 ~ 2.5A
RATED POWER
60W
60W
60W
60W
RIPPLE & NOISE (max.) Note.2 2Vp-p
2.4Vp-p
1.8Vp-p
2.4Vp-p
VOLTAGE ADJ. RANGE (SVR1) 10.8 ~ 13.5V 13.5 ~ 17V 17 ~ 22V 22 ~ 27V
CURRENT ADJ. RANGE(SVR2) 3.75 ~ 5A 3 ~ 4A
2.3 ~ 3A 1.9 ~ 2.5A
VOLTAGE TOLERANCE Note.3 10%
LINE REGULATION
3.0%
LOAD REGULATION
5.0%
SETUP TIME
1400ms / 230VAC 2800ms / 115VAC at full load
0 ~ 2A
60W
3Vp-p
27 ~ 33V
1.5 ~ 2A
0 ~ 1.7A
61.2W
3.6Vp-p
33 ~ 40V
1.3 ~ 1.7A
0 ~ 1.45A
60.9W
4Vp-p
37 ~ 46V
1.1 ~ 1.45A
0 ~ 1.3A
62.4W
4.6Vp-p
43 ~ 53V
1 ~ 1.3A
0 ~ 1.15A
62.1W
5Vp-p
49 ~ 58V
0.9 ~ 1.15A
INPUT
VOLTAGE RANGE Note.4 90 ~ 295VAC 127 ~ 417VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
86%
87%
88%
89%
90%
90%
90%
91%
91%
AC CURRENT (Typ.)
0.8A/115VAC 0.4A/230VAC 0.3A/277VAC
INRUSH CURRENT (Typ.) 45A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER CURRENT
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
14.5 ~ 17V 17.5 ~ 21V 22.8 ~ 26V 28 ~ 34V 34 ~ 38V 41 ~ 46V 47 ~ 52V
Protection type : Shut down o/p voltage, re-power on to recover
54 ~ 60V
59 ~ 65V
OVER TEMPERATURE
85 10 (RTH1)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL879, UL8750, CSA C22.2 No. 207-M89, CSA C22.2 No. 250.0-08, TUV EN61347-1, EN61347-2-13, IP66, J61347-1, J61347-2-13 approved
WITHSTAND VOLTAGE
SAFETY &
EMC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), criteria A
MTBF
OTHERS DIMENSION
523.4Khrs min. MIL-HDBK-217F (25 )
185*62.5*40.5mm (L*W*H)
PACKING
0.56Kg;24pcs/14.4Kg/1.11CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:CEN-60-SPEC 2012-03-20