English
Language : 

CEN-60 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 60W Single Output LED Power Supply
60W Single Output LED Power Supply
CEN-60 series
½ Features :
Universal AC input / Full range (up to 295VAC)
Protections: Short circuit / Overload / Over voltage / Over temperature
Output voltage and constant current level adjustable
Built-in active PFC function
IP66 design for indoor or outdoor installations
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
SPECIFICATION
F 110 M M SELV IP66
MODEL
CEN-60-12 CEN-60-15 CEN-60-20 CEN-60-24 CEN-60-30 CEN-60-36 CEN-60-42 CEN-60-48 CEN-60-54
DC VOLTAGE
12V
15V
20V
24V
30V
36V
42V
48V
54V
CONSTANT CURRENT OPERATION VOLTAGE Note.5 9 ~ 12V
11.25 ~ 15V 15 ~ 20V 18 ~ 24V 22.5 ~ 30V 27 ~ 36V 31.5 ~ 42V 36 ~ 48V 40.5 ~ 54V
RATED CURRENT
5A
4A
3A
2.5A
2A
1.7A
1.45A
1.3A
1.15A
CURRENT RANGE
0 ~ 5A
0 ~ 4A
0 ~ 3A
0 ~ 2.5A 0 ~ 2A
0 ~ 1.7A 0 ~ 1.45A 0 ~ 1.3A 0 ~ 1.15A
RATED POWER
60W
60W
60W
60W
60W
61.2W
60.9W
62.4W
62.1W
RIPPLE & NOISE (max.) Note.2 2Vp-p
2.4Vp-p
1.8Vp-p
2.4Vp-p
3Vp-p
3.6Vp-p
4Vp-p
4.6Vp-p 5Vp-p
OUTPUT VOLTAGE ADJ. RANGE (SVR1) 10.8 ~ 13.5V 13.5 ~ 17V 17 ~ 22V 22 ~ 27V 27 ~ 33V 33 ~ 40V 37 ~ 46V 43 ~ 53V 49 ~ 58V
CURRENT ADJ. RANGE(SVR2) 3.75 ~ 5A 3 ~ 4A
2.3 ~ 3A 1.9 ~ 2.5A 1.5 ~ 2A 1.3 ~ 1.7A 1.1 ~ 1.45A 1 ~ 1.3A 0.9 ~ 1.15A
VOLTAGE TOLERANCE Note.3 10%
LINE REGULATION
3.0%
LOAD REGULATION
5.0%
SETUP TIME
1400ms / 230VAC 2800ms / 115VAC at full load
VOLTAGE RANGE Note.4 90 ~ 295VAC 127 ~ 417VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC ; PF>0.97 / 115VAC PF>0.95 / 230VAC at full load
INPUT EFFICIENCY (Typ.)
86%
87%
88%
89%
90%
90%
90%
91%
91%
AC CURRENT (Typ.)
0.8A/115VAC 0.4A/230VAC
INRUSH CURRENT (Typ.) 45A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER CURRENT
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
Hiccup mode, recovers automatically after fault condition is removed
14.5 ~ 17V 17.5 ~ 21V 22.8 ~ 26V 28 ~ 34V 34 ~ 38V
Protection type : Shut down o/p voltage, re-power on to recover
41 ~ 46V
47 ~ 52V
54 ~ 60V
59 ~ 65V
OVER TEMPERATURE
85 10 (RTH1)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-30 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750, TUV EN61347-1, EN61347-2-13, IP66 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55015
EMC
HARMONIC CURRENT
Compliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61547, light industry level (surge 4KV), criteria A
MTBF
523.4Khrs min. MIL-HDBK-217F (25 )
DIMENSION
183*62.5*40.5mm (L*W*H)
PACKING
0.56Kg;24pcs/14.4Kg/1.11CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
Direct connecting to LEDs is not suggested for models with “RIPPLE & NOISE” > 10% and using additional drivers is highly recommended.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:CEN-60-SPEC 2010-09-01