English
Language : 

CEN-100_12 Datasheet, PDF (1/3 Pages) Mean Well Enterprises Co., Ltd. – 100W Single Output LED Power Supply
100W Single Output LED Power Supply
CEN-100 series
½ Features :
Universal AC input / Full range (up to 295VAC)
Protections: Short circuit / Over current / Over voltage / Over temperature
Output voltage and constant current level adjustable
Built-in active PFC function
IP66 design for indoor or outdoor installations
Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
SPECIFICATION
MODEL
F 110 SELV IP66
CEN-100-20 CEN-100-24
( for 48V,54V only)
CEN-100-30 CEN-100-36
( except for 48V,54V )
CEN-100-42
CEN-100-48
CEN-100-54
OUTPUT
INPUT
DC VOLTAGE
20V
24V
30V
36V
42V
48V
54V
CONSTANT CURRENT OPERATION VOLTAGE Note.5 13 ~ 20V
15.6 ~ 24V
19.5 ~ 30V
23.4 ~ 36V
27.3 ~ 42V
31.2 ~ 48V
35.1 ~ 54V
RATED CURRENT
4.8A
4A
3.2A
2.65A
2.28A
2A
1.77A
CURRENT RANGE
0 ~ 4.8A
0 ~ 4A
0 ~ 3.2A
0 ~ 2.65A
0 ~ 2.28A
0 ~ 2A
0 ~ 1.77A
RATED POWER
96W
96W
96W
95.4W
95.76W
96W
95.58W
RIPPLE & NOISE (max.) Note.2 2.0Vp-p
2.7Vp-p
3Vp-p
3.6Vp-p
4Vp-p
4.6Vp-p
5Vp-p
VOLTAGE ADJ. RANGE (SVR1) 17 ~ 22V
22 ~ 27V
27 ~ 33V
33 ~ 40V
37 ~ 46V
43 ~ 53V
49 ~ 58V
CURRENT ADJ. RANGE(SVR2) 3.12 ~ 4.8A
2.6 ~ 4A
2.08 ~ 3.2A
1.72 ~ 2.65A 1.48 ~ 2.28A
1.3 ~ 2A
1.15 ~ 1.77A
VOLTAGE TOLERANCE Note.3 10%
LINE REGULATION
3.0%
LOAD REGULATION
5.0%
SETUP TIME
3000ms / 230VAC 5000ms / 115VAC at full load
VOLTAGE RANGE Note.4 90 ~ 295VAC 127 ~ 417VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
88%
89%
90%
90%
90%
91%
91%
AC CURRENT (Typ.)
1.4A/115VAC 0.7A/230VAC 0.5A/277VAC
INRUSH CURRENT (Typ.) 60A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER CURRENT
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
Hiccup mode, recovers automatically after fault condition is removed
22.8 ~ 26V
28 ~ 32V
34 ~ 38V
41 ~ 46V
Protection type : Shut down o/p voltage, re-power on to recover
47 ~ 52V
54 ~ 60V
59 ~ 65V
OVER TEMPERATURE
100 10 (RTH1)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750, CSA C22.2 No. 250.0-08(except for 48V, 54V), TUV EN61347-1, EN61347-2-13, IP66, J61347-1, J61347-2-13 approved
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG: >100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 65% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), criteria A
MTBF
519.5Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
195*62.5*40.5mm (L*W*H)
PACKING
0.6Kg; 24pcs/15.4Kg/1.11CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 65% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:CEN-100-SPEC 2012-03-20