English
Language : 

APV-25_17 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – CONSTANT VOLTAGE MODE POWER SUPPLY
25W Single Output Switching Power Supply
APV-25 series
■ Features :
Constant voltage mode power supply
Universal AC input / Full range
Withstand 300VAC Surge input for 5 seconds
Protections: Short circuit / Over load / Over voltage
Fully isolated plastic case
Cooling by free air convection
Small and compact size
IP42 design
Class 2 power unit
Pass LPS
100% full load burn-in test
Low cost, high reliability
Suitable for LED lighting and moving sign applications
2 years warranty
SPECIFICATION
IP42 LPS
MODEL
APV-25-5
APV-25-12
APV-25-15
APV-25-24
APV-25-36
OUTPUT
INPUT
DC VOLTAGE
5V
12V
15V
24V
RATED CURRENT
3.5A
2.1A
1.68A
1.05A
CURRENT RANGE
0 ~ 3.5A
0 ~ 2.1A
0 ~ 1.68A
0 ~ 1.05A
RATED POWER
17.5W
25.2W
25.2W
25.2W
RIPPLE & NOISE (max.) Note.2 120mVp-p
150mVp-p
150mVp-p
150mVp-p
VOLTAGE TOLERANCE Note.3 ±5.0%
LINE REGULATION
±1.0%
LOAD REGULATION
±2.0%
SETUP, RISE TIME Note.6 1500ms, 30ms / 230VAC
1500ms,30ms / 115VAC at full load
HOLD UP TIME (Typ.)
20ms/230VAC 12ms/115VAC at full load
VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
75.5%
82%
83%
83%
AC CURRENT
0.4A/230VAC 0.8A/115VAC
INRUSH CURRENT(Typ.)
COLD START 45A(twidth=310μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
9 units (circuit breaker of type B) / 15 units (circuit breaker of type C) at 230VAC
36V
0.7A
0 ~ 0.7A
25.2W
150mVp-p
84%
LEAKAGE CURRENT
0.25mA / 240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.95V
13.8 ~ 16.2V
17.25 ~ 21V
27 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
41.4 ~ 48.6V
WORKING TEMP.
-30 ~ 70℃(Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750 , CSA-C22.2 No. 250.0-13, IP42 approved; design refer to EN60950-1
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
EMC EMISSION
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022,EN61000-3-2 Class A,EN61000-3-3
EMC IMMUNITY
Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A
MTBF
692.8K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION
84*57*29.5mm (L*W*H)
NOTE
PACKING
0.13Kg; 72pcs / 10.4Kg / 0.92CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7.The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
File Name:APV-25-SPEC 2016-11-10