English
Language : 

APV-12 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 12W Single Output Switching Power Supply
12W Single Output Switching Power Supply
APV-12 series
Features :
Constant voltage design
Universal AC input / Full range
Protections: Short circuit / Over current / Over voltage
Fully isolated plastic case
Cooling by free air convection
Small and compact size
Pass LPS
Suitable for LED lighting and moving sign applications
100% full load burn-in test
Low cost, high reliability
2 years warranty
SPECIFICATION
F 110 SELV
LPS
MODEL
APV-12-5
APV-12-12
APV-12-15
APV-12-24
DC VOLTAGE
5V
RATED CURRENT
2A
12V
15V
24V
1A
0.8A
0.5A
OUTPUT
CURRENT RANGE
0 ~ 2A
0 ~ 1A
0 ~ 0.8A
RATED POWER
10W
12W
12W
RIPPLE & NOISE (max.) Note.2 100mVp-p
120mVp-p
120mVp-p
VOLTAGE TOLERANCE Note.3 5.0%
LINE REGULATION
1.0%
LOAD REGULATION
2.0%
SETUP, RISE TIME Note.6 1500ms, 30ms / 230VAC
1500ms,30ms / 115VAC at full load
HOLD UP TIME (Typ.)
20ms/230VAC 15ms/115VAC at full load
0 ~ 0.5A
12W
150mVp-p
VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
76%
82%
82%
84%
INPUT
AC CURRENT
0.2A/230VAC 0.35A/115VAC
INRUSH CURRENT(max.) COLD START 35A/115VAC 70A/230VAC
LEAKAGE CURRENT
0.25mA / 240VAC
OVER CURRENT
PROTECTION
OVER VOLTAGE
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16V
17.5 ~ 21V
Protection type : Shut off o/p voltage, clamping by zener diode
27.6 ~ 32.4V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
Design refer to TUV EN60950-1, EN61347-2-13,UL8750
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3.75KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015,EN61000-3-2 Class A,EN61000-3-3
OTHERS
NOTE
EMC IMMUNITY
Compliance to EN61547,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A
MTBF
1145.7K hrs min. MIL-HDBK-217F (25 )
DIMENSION
77*40*29(L*W*H)
PACKING
0.08Kg; 120pcs/11.8Kg/0.93CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:APV-12-SPEC 2011-07-09