APC-25_17 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – CONSTANT CURRENT MODE POWER SUPPLY
25W Single Output Switching Power Supply
APC-25 series
■ Features :
Constant current mode power supply
Universal AC input / Full range
Withstand 300VAC Surge input for 5 seconds
Protections:Short circuit / Over voltage
Fully isolated plastic case
Small and compact size
Cooling by free air convection
IP42 design
100% full load burn-in test
Suitable for LED lighting and moving sign applications
Low cost / High reliability
2 years warranty
SPECIFICATION
( only for APC-25-500)
IP42 LPS (only for APC-25-700&1050)
(except for APC-25-350)
MODEL
APC-25-350
APC-25-500
APC-25-700
APC-25-1050
OUTPUT
INPUT
RATED CURRENT
350mA
500mA
700mA
DC VOLTAGE RANGE
25~70V
15~50V
11~36V
RATED POWER
24.5W
25.2W
25.2W
RIPPLE & NOISE (max.) Note.2 300mVp-p
300mVp-p
300mVp-p
VOLTAGE TOLERANCE Note.3 ±5.0%
CURRENT ACCURACY
±8.0%
LINE REGULATION
±1.0%
LOAD REGULATION
±3.0%
SETUP, RISE TIME
1500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load
HOLD UP TIME (Typ.)
20ms/230VAC 12ms/115VAC at full load
VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
83%
83%
83%
AC CURRENT
0.4A/230VAC;0.8A/115VAC
INRUSH CURRENT(Typ.)
COLD START 45A(twidth=310μs measured at 50% Ipeak) at 230VAC
1050mA
9~24V
25.2W
300mVp-p
83%
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
9 units (circuit breaker of type B) / 15 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
0.25mA / 240VAC
PROTECTION OVER VOLTAGE
76 ~ 94V
55 ~ 68V
41 ~ 49V
Protection type : Shut down o/p voltage, re-power on to recover
27 ~ 35V
WORKING TEMP.
-30 ~ 70℃(Refer to "Derating Curve")
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
20 ~ 90% RH non-condensing
-40 ~ +80℃, 10 ~ 95% RH
±0.2%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY &
EMC
(Note 5)
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
UL8750 (except for APC-25-350), CSA-C22.2 No. 250.0-13 (only for APC-25-700&1050), IP42 approved; design refer to EN60950-1
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022,EN61000-3-2 Class A,EN61000-3-3
Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A
MTBF
518.9K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION
PACKING
84*57*29.5(L*W*H)
0.13Kg; 72pcs/10.4Kg/0.92CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristic for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6.The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
File Name: APC-25-SPEC 2016-11-10