English
Language : 

APC-12 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 12W Single Output Switching Power Supply
12W Single Output Switching Power Supply
APC-12 series
Features :
Constant current design
Universal AC input / Full range
Protections:Short circuit / Over current / Over voltage
Fully isolated plastic case
Small and compact size
Cooling by free air convection
Pass LPS
Suitable for LED lighting and moving sign applications
100% full load burn-in test
Low cost / High reliability
SPECIFICATION
2 years warranty
F 110 SELV
LPS
MODEL
APC-12-350
APC-12-700
RATED CURRENT
350mA
DC VOLTAGE RANGE
9~36V
RATED POWER
12.6W
RIPPLE & NOISE (max.) Note.2 300mVp-p
700mA
9~18V
12.6W
250mVp-p
VOLTAGE TOLERANCE Note.3 5.0%
OUTPUT CURRENT ACCURACY
5.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
1.0%
3.0%
3000ms, 180ms / 230VAC
3000ms, 150ms / 115VAC at full load
HOLD UP TIME (Typ.)
20ms/230VAC,15ms/115VAC at full load
VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY(Typ.)
82%
80%
AC CURRENT
0.2A/230VAC;0.35A/115VAC
INRUSH CURRENT(max.) Cold start 35A/115VAC,70A/230VAC
LEAKAGE CURRENT
PROTECTION OVER VOLTAGE
0.25mA / 240VAC
39.6~ 46.8V
Protection type : Shut off o/p voltage, clamping by zener diode
20.7~ 24.3V
WORKING TEMP.
-30 ~ 70 (Refer to "Derating Curve")
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.2%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Design refer to TUV EN60950-1, EN61347-2-13, UL8750
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note 5) EMC EMISSION
EMC IMMUNITY
MTBF
I/P-O/P:3.75KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015,EN61000-3-2 Class A,EN61000-3-3
Compliance to EN61547,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A
1145.7K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
PACKING
77*40*29(L*W*H)
0.08Kg; 120pcs/11.8Kg/0.93CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristic for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name: APC-12-SPEC 2011-07-09