English
Language : 

ADD-155 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 155W Dual Output with Battery Charger(USP Function)
A D D - 1 5 5 155W Dual Output with Battery Charger(USP Function)
series
Features :
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage
Battery low/battery polarity protections
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at PFC 67KHz, PWM 134KHz
2 years warranty
SPECIFICATION
MODEL
ADD-155A
ADD-155B
ADD-155C
OUTPUT NUMBER
CH1
CH2
CH3
CH1
CH2
CH3
CH1
CH2
CH3
DC VOLTAGE
13.8V
5V
13.3V
27.6V
5V
27.1V
54V
5V
53.5V
RATED CURRENT
9.5A
3A
0.5A
4.5A
3A
0.5A
2.3A
3A
0.2A
CURRENT RANGE
0 ~ 10.5A 0 ~ 3A
--------
0 ~ 5A
0 ~ 3A
--------
0 ~ 2.5A 0 ~ 3A
--------
OUTPUT
RATED POWER
152.75W
RIPPLE & NOISE (max.) Note.2 150mVp-p 100mVp-p
VOLTAGE ADJ. RANGE
CH1: 12 ~ 14.5V
VOLTAGE TOLERANCE Note.3 2.0%
3.0%
LINE REGULATION
1.0%
0.5%
--------
--------
--------
152.75W
200mVp-p 100mVp-p
CH1: 24 ~ 29V
1.0%
3.0%
1.0%
0.5%
--------
--------
--------
149.9W
240mVp-p 100mVp-p
CH1: 48 ~ 58V
1.0%
5.0%
1.0%
0.5%
--------
--------
--------
LOAD REGULATION
1.0%
2.0%
--------
1.0%
2.0%
--------
1.0%
2.0%
--------
SETUP, RISE TIME
1000ms, 90ms/230VAC 2000ms, 90ms/115VAC at full load
HOLD UP TIME (Typ.)
24ms/230VAC 20ms/115VAC at full load
VOLTAGE RANGE
88 ~ 264VAC 124 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.92 at full load
INPUT
EFFICIENCY (Typ.)
78%
81%
81%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
2.5A/115VAC 1.5A/230VAC
COLD START 20A/115VAC 40A/230VAC
<1mA / 240VAC
OVERLOAD
PROTECTION OVER VOLTAGE
BATTERY LOW
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
CH1,CH2:105 ~ 135% CH3:0.51 ~ 0.9A rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is reoved
CH1:15.87 ~ 18.63V
CH1:31.74 ~ 37.26V
CH1:62.1 ~ 72.9V
Protection type : Shut down o/p voltage, re-power on to recover
10V 0.8V
19.5V(+1.5V,-1V )
39V 2V
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 ) on +5V ouput
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY &
EMC
(Note 4)
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
164.2K hrs min. MIL-HDBK-217F (25 )
DIMENSION
199*110*50mm (L*W*H)
PACKING
1Kg; 16pcs/16Kg/0.95CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:ADD-155-SPEC 2008-10-08