13.OPERATING CONDITIONS
13-1. At Device Power-Up and Power-Down
AC timing illustrated in "Figure 67. AC Timing at Device Power-Up" and "Figure 68. Power-Down Sequence" are
for the supply voltages and the control signals at device power-up and power-down. If the timing in the figures is
ignored, the device will not operate correctly.
During power-up and power-down, CS# needs to follow the voltage applied on VCC to keep the device not to be
selected. The CS# can be driven low when VCC reach Vcc(min.) and wait a period of tVSL.
Figure 67. AC Timing at Device Power-Up
VCC(min)
VCC
GND
tVR
tSHSL
CS#
tCHSL
tSLCH
tCHSH
tSHCH
SCLK
tDVCH
tCHCL
tCHDX
tCLCH
SI
MSB IN
LSB IN
High Impedance
SO
Symbol
tVR
Parameter
VCC Rise Time
Notes
1
Min.
20
Max.
500000
Unit
us/V
Notes :
1. Sampled, not 100% tested.
2. For AC spec tCHSL, tSLCH, tDVCH, tCHDX, tSHSL, tCHSH, tSHCH, tCHCL, tCLCH in the figure, please refer to
"Table 14. AC Characteristics".