MX25L2026E Datasheet, PDF (18/48 Pages) Macronix International – 2M-BIT [x 1/x 2] CMOS SERIAL FLASH
MX25L2026E
The RDP instruction is for releasing from Deep Power Down Mode.
(14) Read Identification (RDID)
The RDID instruction is for reading the manufacturer ID of 1-byte and followed by Device ID of 2-byte. The Macronix
Manufacturer ID and Device ID are listed as table of "ID Definitions".
The sequence is shown as Figure 25.
While Program/Erase operation is in progress, it will not decode the RDID instruction, so there's no effect on the cy-
cle of program/erase operation which is currently in progress. When CS# goes high, the device is at standby stage.
(15) Read Electronic Manufacturer ID & Device ID (REMS)
The REMS instruction is an alternative to the Release from Power-down/Device ID instruction that provides both the
JEDEC assigned manufacturer ID and the specific device ID.
The REMS instruction is very similar to the Release from Power-down/Device ID instruction. The instruction is initi-
ated by driving the CS# pin low and shift the instruction code "90h" followed by two dummy bytes and one bytes ad-
dress (A7~A0). After which, the Manufacturer ID for Macronix (C2h) and the Device ID are shifted out on the falling
edge of SCLK with most significant bit (MSB) first as shown in Figure 26. The Device ID values are listed in Table 5.
ID Definitions. If the one-byte address is initially set to 01h, then the device ID will be read first and then followed by
the Manufacturer ID. The Manufacturer and Device IDs can be read continuously, alternating from one to the other.
The instruction is completed by driving CS# high.
Table 5. ID Definitions
Command Type
RDID Command
RES Command
REMS Command
MX25L2026E
manufacturer ID memory type
C2
20
electronic ID
11
manufacturer ID
C2
memory density
12
device ID
11
P/N: PM1580
18
REV. 1.4, NOV. 14, 2013