English
Language : 

80387DX Datasheet, PDF (5/17 Pages) Maxwell Technologies – Math Coprocessor
Math Coprocessor
80387DX
TABLE 8. 80387DX TIMING REQUIREMENTS OF THE BUS INTERFACE UNIT (OUTPUT TRIP LEVEL = 1.5V)
(VCC = 4.75V TO 5.25V; TA = -55 TO +125°C, UNLESS OTHERWISE SPECIFIED)
PARAMETER
CONDITIONS
SYMBOL
MIN
MAX
UNIT
386CLK2 Period1
-16
-20
-25
At 2.0V
t1
ns
31
125
25
125
20
125
386CLK2 High Time
-16
-20
-25
At 2.0V
t2a
ns
9
--
8
--
7
--
386CLK2 High Time1
-16
-20
-25
At 3.7V
t2b
ns
5
--
5
--
4
--
386CLK2 Low Time
-16
-20
-25
386CLK2 Low Time1
-16
-20
-25
386CLK2 Fall Time1
-16
-20
-25
At 2V
At 0.8V
At 3.7V to 0.8V
t3a
ns
9
--
8
--
7
--
t3b
ns
7
--
6
--
5
--
t4
ns
--
8
--
8
--
7
386CLK2 Rise Time1
-16
-20
-25
At 0.8V to 3.7V
t5
ns
--
8
--
8
--
7
386 CLK2/387CLK2 Ratio
--
10/16
14/10
--
READYO Out Delay
-16
-20
-25
CL = 50 pF
t7
ns
4
34
3
31
3
24
PEREQ, ERROR Out Delay
-16
-20
-25
CL = 50 pF
t7
ns
5
34
5
34
4
33
BUSY Out Delay
-16
-20
-25
CL = 50 pF
t7
ns
5
34
5
29
4
29
05.07.02 REV 1
All data sheets are subject to change without notice 5
©2002 Maxwell Technologies
All rights reserved.