English
Language : 

306RPFX Datasheet, PDF (5/16 Pages) Maxwell Technologies – 16-Channel CMOS Analog Multiplexer
16-Channel CMOS Analog Multiplexer
306
PARAMETER
SYMBOL
TEST CONDITIONS
SUBGROUPS MIN TYP MAX UNITS
Enable Turn-On Time
tON(EN) Figure 11
Enable Turn-Off Time
tOFF(EN) Figure 11
Charge Injection1
Off Isolation5
Crosstalk Between Chan-
nels
Logic Input Capacitance
NO-Off Capacitance
Q CL = 1.0 nF,
VNO = 0V,
RS = 0Ω,
Figure 13
VISO VEN = 0V,
RL = 1 kΩ,
f = 100 kHz,
Figure 14
VCT VEN = 2.4V,
f = 100 kHz,
VGEN = 1V p-p,
RL = 1 kΩ,
Figure 15
CIN
CNO(OFF)
f = 1 MHz
f = 1 MHz
VEN = VNO = 0V
Figure 16
TA = +25°C
TA = -55 TO +125°C
TA = +25°C
TA = -55 TO +125°C
TA = +25°C
TA = +25°C
TA = +25°C
TA = +25°C
TA = +25°C
9
10, 11
9
10, 11
9
9
9
9
9
-- 130 200 ns
400
-- 55 150 ns
300
-- 2 10 pC
-- -69 -- dB
-- -92 -- dB
--
8
-- pF
--
8
-- pF
COM-Off Capacitance
CCOM(OFF) f = 1 MHz
VEN = 2.4V
Figure 16
TA = +25°C
9
-- 130 -- pF
COM-On Capacitance
CCOM(ON) f = 1 MHz
VEN = 0.8V
Figure 16
TA = +25°C
9
-- 140 -- pF
1. Guaranteed by design.
2. Characterized and not 100% tested.
3. ∆RON = RON(MAX) - RON(MIN). On-resistance match between channels and flatness are guaranteed only with specified volt-
ages. Flatness is defined as the difference between the maximum and minimum value of on-resistance as measured at the
extremes of the specified analog signal range.
4. Leakage parameters are 100% tested at the maximum rated hot temperature and guaranteed by correlation at +25°C.
5. Off isolation = 20log VCOM/VNO, where VCOM = output and VNO = input to off switch.
08.15.02 Rev 5
All data sheets are subject to change without notice 5
©2002 Maxwell Technologies