English
Language : 

HSN3000 Datasheet, PDF (1/5 Pages) Maxwell Technologies – Nuclear Event Detector
HSN-3000
Nuclear Event Detector
VB
Threshold
8
9 Adjust
Detector
(Pin Diode)
Amplifier
VH
14
Pulse Timer
BIT 6
LED
7
GND
5
4
C
RC
Logic Diagram
VL
1
10 kΩ
2 NED
Logic
Latch
12
Flag
Reset
10 kΩ
13 NEF
11 Flag
Reset
FEATURES:
DESCRIPTION:
• Detects ionizing radiation pulses
• 100% tested/certified detection threshold level
• Adjustable circumvention period
• Flag remembers event occurred
• 100% testable with built-in test
• Detection threshold adjustability
• Single +5V operation
• Radiation hardness guaranteed
• Compliant to MIL-PRF-38534 Class H1
• Flat pack (F) or DIP (L) packages
RADIATION HARDNESS
CHARACTERISTICS:
• Dose Rate (operate-through): 1 x 1012 rad(Si)/sec
• Total Dose: 1 x 106 rad(Si)
• Neutron Fluence: 5 x 1013 n/cm2
• Approximate Detection Range: 2 x 105 - 2 x 107 rad(Si)/sec
• Maxwell Technologies Specified, Controlled, Tested and
Guaranteed
Maxwell Technologies’ HSN-3000 radiation-hardened Hybrid
Nuclear Event Detector (NED) senses ionizing radiation pulses
generated by a nuclear event, such as the detonation of a nuclear
weapon, and rapidly switches its outputs from the normal high
state to a low state with a propagation delay time of less than
20ns. The active low Nuclear Event Detection signal (NED) is
used to initiate a wide variety of circumvention functions, thus
preventing upset and burnout of electronic components. The NED
output is also used to initiate both hardware and software recov-
ery. The Nuclear Evet Flag signal (NEF) remembers the event
occurred and is used to distinguish between an actual event and
power up. The signal input of either Flag Reset or Flag Reset can
be used to reset the NEF output. This high-speed, 14-pin hybrid
detector is used in electronic systems as a general-purpose cir-
cumvention device to protect memory, stop data processing, and
drive power supply switches as well as signal clamps.
The HSN-3000 is guaranteed to operate through three critical
environments: ionizing dose rate [1012 rad(Si)/s], gamma total
dose [106 rad(Si)], and neutron fluence [5 x 1013 n/cm2]. In addi-
tion, the device is designed to function throughout the transient
neutron pulse. The hybrid’s discrete design ensures a controlled
response in these radiation environments as well as immunity to
latchup. Each HSN-3000’s detection level and functionality are
tested in an ionizing dose rate environment. A certificate is pro-
vided with each serialized hybrid, reporting the radiation test
results and guaranteeing its performance. The device is also lot
qualified in the total dose and neutron environments to ensure
performance.
The detection threshold of the HSN-3000 is adjustable within the
range of 2 x 105 rad(Si)/s to 2 x 107 rad(Si)/s. This detection level
can be preset by Maxwell or adjusted by the user. Less than a
30% variation in detection threshold can be expected over the
entire operating temperature range.
1. Manufactured for Maxwell Technologies by Teledyne Microelectronic
Technologies to MIL-PRF-38534, Class H, No RHA
01.07.05 Rev 3
All data sheets are subject to change without notice 1
(858) 503-3300 - Fax: (858) 503-3301 - www.maxwell.com
©2005 Maxwell Technologies
All rights reserved.