English
Language : 

MAX4511 Datasheet, PDF (7/16 Pages) Maxim Integrated Products – Quad, Rail-to-Rail, Fault-Protected, SPST Analog Switches
Quad, Rail-to-Rail, Fault-Protected,
SPST Analog Switches
__________________________________________Typical Operating Characteristics
(TA = +25°C, unless otherwise noted.)
SWITCH ON-RESISTANCE
vs. VCOM (DUAL SUPPLIES)
350
V+ = +5V
300
V- = -5V
250
V+ = +10V
200
V- = -10V
V+ = +12V
V- = -12V
150
100
V+ = +15V
50
V- = -15V
0
-20 -15 -10
-5 0 5
VCOM (V)
V+ = +20V
V- = -20V
10 15 20
SWITCH ON-RESISTANCE vs. VCOM
AND TEMPERATURE (SINGLE SUPPLY)
400
350
TA = +125°C TA = +85°C
300
250
TA = +25°C TA = -40°C
200
150
100
TA = -55°C
50
V+ = +12V
0
02
468
VCOM (V)
10 12
ON AND OFF TIMES
vs. SUPPLY VOLTAGE
1000
900
800
tON
700
(DUAL SUPPLIES)
tON
(SINGLE SUPPLY)
600
500
400
300
200
100
tOFF
(DUAL SUPPLIES)
0
0
5
10
tOFF
(SINGLE
SUPPLY)
15
20
SUPPLY VOLTAGE (±V)
SWITCH ON-RESISTANCE vs. VCOM AND
TEMPERATURE (DUAL SUPPLIES)
200
180
TA = +125°C TA = +85°C
160
140
120
100
80
60 TA = -55°C TA = -40°C
TA = +25°C
40
20 V+ = +15V
V- = -15V
0
-15 -10 -5 0
5
VCOM (V)
10 15
ID(ON), IS(OFF), AND ID(OFF)
LEAKAGES vs. TEMPERATURE
100n
ICOM(OFF) @VNO = -14V,
10n
VCOM = +14V
ICOM(OFF) @VNO = +14V,
VCOM = -14V
1n
ICOM(ON) @VNO
= VCOM = -14V
100p
ICOM(ON) @VNO
= VCOM = +14V
INO(OFF) @VNO = -14V,
10p
VCOM = +14V
INO(OFF) @VNO = +14V,
VCOM = -14V
1p
-50 -25 0 25 50 75 100 125 150
TEMPERATURE (°C)
ON AND OFF TIMES
vs. TEMPERATURE
600
500
tON
400
300
200
tOFF
100
0
-50 -25
0 25 50 75 100 125
TEMPERATURE (°C)
SWITCH ON-RESISTANCE
vs. VCOM (SINGLE SUPPLY)
1000
V+ = +5V
V- = 0
V+ = +15V
V+ = +12V
V+ = +20V
V+ = +24V
V+ = +30V
100
0 5 10 15 20 25 30
VCOM (V)
CHARGE INJECTION
vs. VCOM (DUAL SUPPLIES)
14
V+ = +15V
12
V- = -15V
10
DUAL ±15V
8
SUPPLIES
6
4
SINGLE +12V
SUPPLY
2
0
-15 -10
-5 0 5
VCOM (V)
10 15
POWER-SUPPLY CURRENT
vs. TEMPERATURE
600
500
400
IV+
300
IGND
200
IV-
100
0
-50 -25
0 25 50 75 100 125
TEMPERATURE (°C)
_______________________________________________________________________________________ 7