PON Triplexer Control and
Monitoring Circuit
Table 02h, Register C5h to C6h: Reserved
FACTORY DEFAULT:
READ ACCESS
WRITE ACCESS
0000 0000h
PW2
PW2
MEMORY TYPE:
Nonvolatile (SEE)
These registers are reserved.
Table 02h, Register C7h: M4 LUT Cntl
FACTORY DEFAULT
READ ACCESS
WRITE ACCESS
MEMORY TYPE:
00h
PW2
PW2
Nonvolatile (SEE)
C7h RESERVED RESERVED RESERVED RESERVED RESERVED
bit7
Controls the size and location of LUT functions for the MON4 measurement.
RESERVED
DBL_SB
UP_LOWB
bit0
Bit7:2
Bit1
Bit0
RESERVED: Default = 000000b.
DBL_SB: Chooses the size of LUT for Table 06h.
0 = (Default) Single LUT of 32 bytes.
1 = Double LUT of 16 bytes.
UP_LOWB: Determines which 16-byte LUT is used if DBL_SB = 1. If DBL_SB = 0, the value of this
bit is a don’t care.
0 = (Default) Chooses the lower 16 bytes of Table 06h (Registers 80h-8Fh).
1 = Chooses the upper 16 bytes of Table 06h (Registers 90h-9Fh).
Table 02h, Register C8h to F7h: No Memory
Table 02h, Register F8h to F9h: MAN IBIAS
FACTORY DEFAULT:
READ ACCESS
WRITE ACCESS
00h
PW2
PW2 and (BIAS-EN = 0)
MEMORY TYPE:
Volatile
F8h RESERVED RESERVED
212
211
210
29
28
27
F9h
27
26
25
24
23
22
21
20
bit7
bit0
When BIAS-EN (Table 02h, Register 80h) is written to 0, writes to these bytes will control the IBIAS DAC. See MAN_CNTL (Table 02h,
Register FAh) for details.
62 ____________________________________________________________________