MAX6457–MAX6460
High-Voltage, Low-Current Voltage Monitors in
SOT Packages
Pin Description
PIN
NAME
MAX6457 MAX6458 MAX6459 MAX6460
FUNCTION
MAX6457: Open-Drain Monitor Output. OUT requires an external pullup
resistor. OUT asserts low for VCC between 1.5V and 4V. OUT asserts low
when VIN+ drops below VTH- and goes high after the timeout period (tTP)
when VIN+ exceeds VTH+.
MAX6458: Open-Drain Monitor Output. OUT requires an external pullup
1
1
—
1
OUT resistor. OUT asserts low for VCC between 1.5V and 4V. OUT asserts low
when VIN+ drops below VTH- or when VIN- exceeds VTH+. OUT goes
high after the timeout period (tTP) when VIN+ exceeds VTH+ and VIN-
drops below VTH-.
MAX6460: Open-Drain Monitor Output. OUT requires an external pullup
resistor. OUT asserts low for VCC between 1.5V and 4V. OUT asserts low
when VIN+ drops below VIN-. OUT goes high when VIN+ is above VIN-.
Open-Drain Monitor A Undervoltage Output. OUTA requires an external
—
—
1
—
OUTA
pullup resistor. OUTA goes low when VIN+ drops below VTH- and goes
high when VIN+ exceeds VTH+. OUTA also goes low for VCC between
1.5V and 4V.
Open-Drain Monitor B Overvoltage Output. OUTB requires an external
—
—
5
—
OUTB
pullup resistor. OUTB goes low when VIN- exceeds VTH+ and goes high
when VIN- drops below VTH-. OUTB also goes low when VCC drops
below 4V.
2
2
2
2
GND Ground
3
3
3
3
IN+ Adjustable Undervoltage Monitor Threshold Input. Noninverting input for
MAX6460.
—
4
4
4
IN- Adjustable Overvoltage Monitor Threshold Input. Inverting input for
MAX6460.
Clear Input. For VIN+ > VTH+, drive CLEAR high to latch OUT high.
4
—
—
—
CLEAR
Connect CLEAR to GND to make the latch transparent. CLEAR must be
low when powering up the device. Connect CLEAR to GND when not
used.
—
—
—
5
5
6
Reference. Internal 2.25V reference output. Connect REF to IN+ through
a voltage divider for active-low output. Connect REF to IN- through a
5
REF voltage divider for active-high output. REF can source up to 100µA and
sink up to 300nA. Leave REF floating when not used. REF output is
stable with capacitive loads from 0 to 50pF or greater than 1µF.
6
VCC Supply Voltage
6
Maxim Integrated