English
Language : 

MAX16054 Datasheet, PDF (6/9 Pages) Maxim Integrated Products – On/Off Controller with Debounce and ±15kV ESD Protection
On/Off Controller with Debounce and
±15kV ESD Protection
Human Body Model
Figure 2a shows the Human Body Model, and Figure
2b shows the current waveform it generates when dis-
charged into a low impedance. This model consists of a
100pF capacitor charged to the ESD voltage of interest,
which is then discharged into the test device through a
1.5kΩ resistor.
IEC 61000-4-2
The IEC 61000-4-2 standard covers ESD testing and
performance of finished equipment; it does not specifi-
cally refer to integrated circuits. The MAX16054 helps in
the design of equipment that meets IEC 61000-4-2, with-
out the need for additional ESD-protection components.
The major difference between tests done using the
Human Body Model and IEC 61000-4-2 is higher peak
current in IEC 61000-4-2, because series resistance is
lower in the IEC 61000-4-2 model. Hence, the ESD with-
stand voltage measured to IEC 61000-4-2 is generally
lower than that measured using the Human Body Model.
Figure 3a shows the IEC 61000-4-2 model, and Figure
3b shows the current waveform for the IEC 61000-4-2
ESD Contact-Discharge test.
The Air-Gap test involves approaching the device with a
charged probe. The Contact-Discharge method connects
the probe to the device before the probe is energized.
Machine Model
The Machine Model for ESD tests all pins using a
200pF storage capacitor and zero discharge resis-
tance. Its objective is to emulate the stress caused by
contact that occurs with handling and assembly during
manufacturing.
RC
1MΩ
CHARGE-CURRENT
LIMIT RESISTOR
HIGH-
VOLTAGE
DC
SOURCE
Cs
100pF
RD
1500Ω
DISCHARGE
RESISTANCE
STORAGE
CAPACITOR
DEVICE
UNDER
TEST
RC
50MΩ to 100MΩ
RD
330Ω
CHARGE-CURRENT
LIMIT RESISTOR
DISCHARGE
RESISTANCE
HIGH-
VOLTAGE
DC
SOURCE
Cs
150pF
STORAGE
CAPACITOR
DEVICE
UNDER
TEST
Figure 2a. Human Body ESD Test Model
Figure 3a. IEC 61000-4-2 ESD Test Model
IP 100%
90%
Ir
PEAK-TO-PEAK RINGING
(NOT DRAWN TO SCALE)
I
100%
90%
AMPERES
36.8%
10%
0
0
tRL
TIME
tDL
CURRENT WAVEFORM
Figure 2b. Human Body Current Waveform
10%
tR = 0.7ns TO 1ns
t
30ns
60ns
Figure 3b. IEC 61000-4-2 ESD Generator Current Waveform
6 _______________________________________________________________________________________