English
Language : 

MAX1620 Datasheet, PDF (5/20 Pages) Maxim Integrated Products – Digitally Adjustable LCD Bias Supplies
Digitally Adjustable LCD Bias Supplies
TIMING CHARACTERISTICS
(VDD = 3.3V, VBATT = 10V, TA = -40°C to +85°C. Typical values are at TA = +25°C, unless otherwise noted. Limits over this
temperature range are guaranteed by design.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
MAX1620 (Figure 1)
Pulse Width High (UP, DN)
t1
Pulse Width Low (UP, DN)
t2
Pulse Separation (UP, DN)
t3
Counter Reset Time
t4
MAX1621 (Figures 2 and 3)
1
µs
1
µs
1
µs
1
µs
SDA_ to SCL_ Data-Setup Time
SCL_ to SDA_ Data-Hold Time
SCL/SDA Rise Time
SCL/SDA Fall Time
SCL Low Time
SCL High Time
tSU:DAT
tHD:DAT
tR
tF
tLOW
tHIGH
500
ns
0
ns
1
µs
300 ns
4.7
µs
4
µs
Start Condition SCL_ to SDA_
Setup Time
tSU:STA
4.7
µs
Start Condition SDA_ to SCL_
Hold Time
tHD:STA
4
µs
Stop Condition SCL_ to SDA_
Setup Time
tSU:STO
4
µs
SCL Falling Time to SDA Valid
Master Clocking in Data
tDV
1
µs
Note 1: The setting in the DAC is guaranteed to remain valid as long as VDD is greater than the UVLO threshold.
Note 2: BATT Operating Range is guaranteed by the Microsecond-Volt Time Constant specification.
Note 3: Current sourced from a pin is denoted as positive current. Current sunk into a pin is denoted as negative current.
Note 4: Guaranteed by design.
__________________________________________Typical Operating Characteristics
(VDD = 5V, VBATT = 10V, L1 = 100µH, TA = +25°C, unless otherwise noted.)
EFFICIENCY vs. OUTPUT CURRENT
1.00
0.95
+15V
0.90
+25V
0.85
0.80
0.75
0.70
0
10 20 30 40 50 60 70
OUTPUT CURRENT (mA)
EFFICIENCY vs. OUTPUT CURRENT
1.00
0.95
0.90
-25V
0.85
-15V
0.80
0.75
0.70
0 10 20 30 40 50 60 70
OUTPUT CURRENT (mA)
EFFICIENCY vs. OUTPUT VOLTAGE
1.00
0.95
0.90 +10mA
+20mA
0.85
0.80
0.75
0.70
12 14 16 18 20 22 24 26
OUTPUT VOLTAGE (V)
_______________________________________________________________________________________ 5