English
Language : 

DS1877 Datasheet, PDF (48/65 Pages) Maxim Integrated Products – SFP Controller for Dual Rx Interface
SFP Controller for Dual Rx Interface
Table 02h, Register 8Ch: RESERVED
FACTORY DEFAULT
READ ACCESS
N/A
WRITE ACCESS
N/A
A2h AND B2h MEMORY N/A
MEMORY TYPE
N/A
These registers are reserved.
Table 02h, Register 8Dh: FORCE RSSI
FACTORY DEFAULT
READ ACCESS
WRITE ACCESS
A2h AND B2h MEMORY
MEMORY TYPE
00h
PW2 or (PW1 and RWTBL2) or (PW1 and RTBL2)
PW2 or (PW1 and RWTBL2)
Common A2h and B2h memory locations
Nonvolatile (SEE)
8Dh RESERVED
BIT 7
XOVEREN2
RSSI2_FC
RSSI2_FF
RESERVED
XOVEREN1
RSSI1_FC
RSSI1_FF
BIT 0
BITS 7, 3
BIT 6
BITS 5:4
BIT 2
BITS 1:0
RESERVED
XOVEREN2: Enables RSSI conversion to use the XOVER2 value during RSSI2 conversions.
0 = Uses hysteresis for linear RSSI measurements.
1 = XOVER1 value is enabled for nonlinear RSSI measurements.
RSSI2_FC and RSSI2_FF: RSSI2 force coarse and RSSI2 force fine. Control bits for RSSI mode of
operation on the RSSI2 conversion.
00b = (default) Normal RSSI mode of operation.
01b = The fine settings of scale and offset are used for RSSI2 conversions.
10b = The coarse settings of scale and offset are used for RSSI2 conversions.
11b = Normal RSSI mode of operation.
XOVEREN1: Enables RSSI conversion to use the XOVER1 value during RSSI1 conversions.
0 = Uses hysteresis for linear RSSI measurements.
1 = XOVER1 value is enabled for nonlinear RSSI measurements.
RSSI1_FC and RSSI1_FF: RSSI1 force coarse and RSSI1 force fine. Control bits for RSSI mode of
operation on the RSSI1 conversion.
00b = (default) Normal RSSI mode of operation.
01b = The fine settings of scale and offset are used for RSSI1 conversions.
10b = The coarse settings of scale and offset are used for RSSI1 conversions.
11b = Normal RSSI mode of operation.
48