English
Language : 

MAX3387E_10 Datasheet, PDF (4/14 Pages) Maxim Integrated Products – 3V, ±15kV ESD-Protected, AutoShutdown Plus RS-232 Transceiver for PDAs and Cell Phones
3V, ±15kV ESD-Protected, AutoShutdown Plus
RS-232 Transceiver for PDAs and Cell Phones
TIMING CHARACTERISTICS
(VCC = VL = +3V to +5.5V; C1–C4 = 0.1µF, tested at +3.3V ±10%; C1 = 0.047µF, C2–C4 = 0.33µF, tested at +5.0V ±10%; TA = TMIN
to TMAX, unless otherwise noted. Typical values are at VCC = VL = +3.3V, TA = +25°C.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Maximum Data Rate
RL = 3kΩ, CL = 1000pF,
one transmitter switching
250
kbps
Receiver Propagation Delay
tPHL
Receiver input to receiver output,
tPLH
CL = 150pF
Time to Exit Shutdown
⏐VT_OUT⏐ > +3.7V
Transmitter Skew
⏐tPHL - tPLH⏐ (Note 2)
Receiver Skew
⏐tPHL - tPLH⏐
Transition-Region Slew
Rate
VCC = +3.3V,
TA = +25°C,
RL = 3kΩ to 7kΩ,
measured from +3V
to -3V or -3V to +3V
CL = 150pF to
1000pF
6
CL = 150pF to
2500pF
4
0.15
µs
0.15
100
µs
100
ns
50
ns
30
V/µs
30
Note 2: Transmitter skew is measured at the transmitter zero crosspoints.
(VCC = VL = +3.3V, TA = +25°C, unless otherwise noted.)
TRANSMITTER OUTPUT VOLTAGE
vs. LOAD CAPACITANCE
7.5
5.0
DATA RATE = 250kbps
2.5
LOAD = 3kΩ IN PARALLEL WITH CL
0
-2.5
-5.0
-7.5
0
1000 2000 3000 4000 5000
LOAD CAPACITANCE (pF)
Typical Operating Characteristics
SLEW RATE vs. LOAD CAPACITANCE
16
14
12
SLEW RATE -
10
8
SLEW RATE +
6
4
2
0
0 1000 2000 3000 4000 5000
LOAD CAPACITANCE (pF)
4 _______________________________________________________________________________________