English
Language : 

MAX14588EVKIT Datasheet, PDF (4/8 Pages) Maxim Integrated Products – 4.5V to 36V Operating Voltage Range
MAX14588 Evaluation Kit
Evaluates: MAX14588
Switch Control
The EV kit features two jumpers (JU6, JU8) to enable or
disable the switch. See Table 4 for jumper settings.
Reverse-Current Block Enable
Use jumper JU9 to enable or disable the reverse-current
flow protection. The reverse-current block is enabled
when RIEN is logic-high. See Table 6 for jumper settings.
Current-Limit Type Select
The EV kit features jumpers JU12, JU14, JU15 to select
different current-limit type and sampled time. See Table 7
for jumper settings.
Output Load Capacitor
Use jumper JU13 to connect output to 330µF capacitor.
See Table 9 for jumper settings.
Table 4. Switch Control (JU6, JU8)
JUMPER
SHUNT
POSITION
1-2
JU6
2-3*
Installed*
JU8
Not
installed
*Default position.
DESCRIPTION
HVEN connected to IN
through 100kΩ.
HVEN connected to ground.
EN connected to VBUS.
EN connected to ground
through 100kΩ.
Table 5. Enable Inputs
HVEN
EN
0
0
0
1
1
0
1
1
SWITCH STATUS
On
On
Off
On
Table 6. Reverse-Current Block Enable
(JU9)
JUMPER
JU9
SHUNT
POSITION
Installed*
Not
installed
*Default position.
DESCRIPTION
RIEN connected to VBUS.
RIEN connected to ground
through 100kΩ.
Table 7. Current-Limit Type Select
(JU12, JU14, JU15)
JUMPER
SHUNT
POSITION
1-2*
JU12
2-3
1-2*
JU14
2-3
1-2
JU15
2-3*
*Default position.
DESCRIPTION
CLTS_MODE high. CLTS1
and CLTS2 are sampled
continuously.
CLTS_MODE low. CLTS1 and
CLTS2 are sampled only when
VIN - VOUT < 0.6V.
CLTS1 high.
CLTS1 low.
CLTS2 high.
CLTS2 low.
Table 8. Logic Inputs
CLTS2
0
0
1
1
CLTS1
0
1
0
1
CURRENT-LIMIT TYPE
Latchoff
Autoretry
Continuous
Continuous
Table 9. Output Load Capacitor (JU13)
JUMPER
JU13
SHUNT
POSITION
Installed
Not
installed*
DESCRIPTION
OUT connected to C7 and C8.
OUT not connected to
C7 and C8.
*Default position.
www.maximintegrated.com