DC ELECTRICAL CHARACTERISTICS (continued)
(VCC = +5V ±5%, VCC2 = +3V to +3.6V, TA = TMIN to TMAX, unless otherwise noted. Typical values are at VCC = +5V, VCC2 = +3.3V,
RL = 60Ω, and TA = +25°C.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Input Voltage for Standby
VIH_RS
0.75 x
V
VCC
Slope-Control Mode Voltage
High-Speed Mode Current
ESD Protection
VSLOPE -200µA < IRS < 10µA
0.4 x
VCC
0.6 x
V
VCC
IIL_RS VRS = 0
-500
µA
IEC 61000-4-2 Contact Discharge Method
±8
kV
per IBEE test facility (Note 3)
TIMING CHARACTERISTICS
(VCC = +5V ±5%, VCC2 = +3V to +3.6V, RL = 60Ω, CL = 100pF, TA = TMIN to TMAX, unless otherwise noted. Typical values are at
VCC = +5V, VCC2 = +3.3V, and TA = +25°C.)
PARAMETER
Delay TXD to Bus Active
Delay TXD to Bus Inactive
Delay Bus to Receiver Active
Delay Bus to Receiver Inactive
Delay TXD to RXD Active
(Dominant Loop Delay)
SYMBOL
tONTXD
tOFFTXD
tONRXD
tOFFRXD
CONDITIONS
Figure 1 (Note 4)
Figure 1
(Note 4)
MAX13050/MAX13052/
MAX13053
MAX13054
Figure 1 (Note 4)
Figure 1 (Note 4)
tONLOOP Figure 1 (Note 4)
MIN TYP MAX UNITS
66
110
ns
61
95
ns
70
110
54
115
ns
46
160
ns
121 255
ns
Delay TXD to RXD Inactive
(Recessive Loop Delay)
TOFFLOOP Figure 4 (Note 4)
108 255
ns
Delay TXD to RXD Active
(Dominant Loop Delay) Slew-Rate
Controlled
tONLOOP-S MAX13052
RRS = 24kΩ
(500kbps)
RRS = 100kΩ
(125kbps)
RRS = 180kΩ
(62.5kbps)
280 450
ns
0.82
1.6
µs
1.37
5
RRS = 24kΩ
(500kbps)
386 600
ns
Delay TXD to RXD Inactive (Loop
Delay) Slew-Rate Controlled
tOFFLOOP-S MAX13052
RRS = 100kΩ
(125kbps)
RRS = 180kΩ
(62.5kbps)
0.74
1.6
µs
0.97
5
RRS = 24kΩ
10
(500kbps)
Differential Output Slew Rate
|SR| MAX13052
RRS = 100kΩ
(125kbps)
2.7
V/µs
RRS = 180kΩ
1.6
(62.5kbps)
4 _______________________________________________________________________________________