TIMING CHARACTERISTICS
(VL = +2.7V to +5.5V, BAT = +6V to +26V, SD = VL, TA = -40°C to +125°C, unless otherwise noted. Typical values are at VL = +3.3V,
BAT = +14V, TA = +25°C) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX UNITS
IN0 to DO0 Propagation Delay
IN1 to DO1 Propagation Delay
CLK Frequency
Falling Edge of CS to Rising Edge
of CLK Required Setup Time
tPROP
fCLK
tLEAD
VBAT = 6V
VBAT = +14V
Input rise/fall time < 2ns,
VL = +3.0V to +5.5V
Input rise/fall time < 2ns,
VL = +3.0V to +5.5V, Figure 1
22
22
110
35
µs
5
MHz
ns
Falling Edge of CLK to Rising
Edge of CS Required Setup Time
tLAG
Input rise/fall time < 2ns,
VL = +3.0V to +5.5V, Figure 1
50
ns
SDI Valid to Falling Edge of CLK
Required Setup Time
tSI(SU)
Input rise/fall time < 2ns,
VL = +3.0V to +5.5V, Figure 1
30
ns
Falling Edge of CLK to SDI
Required Hold Time
tSI(HOLD)
Input rise/fall time < 2ns,
VL = +3.0V to +5.5V, Figure 1
20
Time From Falling Edge of CS to
SDO Low Impedance
tSO(EN)
Input rise/fall time < 2ns,
VL = +3.0V to +5.5V, Figure 1
Time From Rising Edge of CS to
SDO High Impedance
tSO(DIS) VL = +3.0V to +5.5V, Figures 1 and 2
ns
55
ns
55
ns
Time from Rising Edge of CLK to
SDO Data Valid
Debounce time
Scanning Time Pulse
Scanning Time Period
Wetting Time Pulse
Time from Shutdown To Normal
Operation
tVALID
tDEB
tSCAN
tSCAN_P
tWET
CSDO =15pF,
VL = +3.0V to +5.5V, Figure 1
CTDEB = 500pF
CTDEB = 10nF (Note 6)
SC2 = 0, SC1 = 1, SC0 = 1
WTOFF = 0
SD low-to-high transition to input
monitoring enabled
70
ns
3.18
5.9
9.42
ms
63
120
188
130
250
400
µs
4
8
14
ms
10
21
35
ms
200
µs
Note 1: All units are 100% production tested at TA = +125°C. Limits over the operating temperature range are guaranteed by
correlation to the +125°C tests.
Note 2: The total supply current is the sum of the current flowing into VL, BAT, and BATREF.
Note 3: VTH_C = (VTH_HIGH + VTH_LOW)/2.
Note 4: VTH_HYS = (VTH_HIGH - VTH_LOW).
Note 5: Wetting current rise/fall time is measured as the time from 10% to 90% of the maximum wetting current.
Note 6: Guaranteed by design.