English
Language : 

ICL761X_1 Datasheet, PDF (4/26 Pages) Maxim Integrated Products – Single/Dual/Triple/Quad Operational Amplifiers
Single/Dual/Triple/Quad
Operational Amplifiers
ABSOLUTE MAXIMUM RATINGS (Single/Dual)
Total Supply Voltage (V+ to V-) ...........................................+18V
Input Voltage ........................................(V+ + 0.3V) to (V- - 0.3V)
Differential Input Voltage (Note 1)......±(V+ + 0.3V) to (V- - 0.3V)
Duration of Output Short Circuit (Note 2) ......................Unlimited
Continuous Power Dissipation (TA = +25°C)
TO-99 Metal Can (derate 2mW/°C above +25°C) .......250mW
8-Pin Minidip (derate 2mW/°C above +25°C) ..............250mW
14-Pin Plastic (derate 3mW/°C above +25°C) .............375mW
14-Pin CERDIP (derate 4mW/°C above +25°C)...........500mW
16-Pin Plastic (derate 3mW/°C above +25°C) .............375mW
16-Pin CERDIP (derate 4mW/°C above +25°C)...........500mW
Operating Temperature Ranges:
M Series .............................................................-55°C to +125°C
E Series................................................................-40°C to +85°C
C Series .................................................................-0°C to +70°C
Storage Temperature Range ............................-55°C to +150°C
Lead Temperature (soldering, 10s) ................................+300°C
Soldering Temperature (reflow)
Lead(Pb)-Free Packages.............................................+260°C
Packages Containing Lead..........................................+240°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
Note 1: Long-term offset voltage stability will be degraded if large input differential voltages are applied for long periods of time.
Note 2: The outputs may be shorted to ground or to either supply for VSUPP ≤ 10V. Care must be taken to insure that the dissipation
rating is not exceeded.
ELECTRICAL CHARACTERISTICS (Single/Dual)
(VSUPP = ±1.0V, IQ = 10µA, TA = +25°C, unless otherwise noted.)
PARAMETER
SYMBOL
CONDITIONS
Input Offset Voltage
Temperature
Coefficient of VOS
Input Offset Current
Input Bias Current
Common-Mode
Voltage Range
(Except ICL7612/
ICL7616)
RS ≤ 100kΩ,
TA = +25°C
VOS
RS ≤ 100kΩ,
TMIN ≤ TA ≤ TMAX
ΔVOS/ΔT RS ≤ 100kΩ
IOS
IBIAS
TA = +25°C
0°C ≤ TA ≤ +70°C
TA = +25°C
0°C ≤ TA ≤ +70°C
VCMR
ICL76XXA
MIN TYP MAX
2
3
10
0.5
30
300
1.0
50
500
-0.4
+0.6
Extended Common-
Mode Voltage Range
(ICL7612 Only)
VCMR
-1.1
+0.6
Extended Common-
Mode Voltage Range
(ICL7616 Only)
Output Voltage Swing
VCMR
VOUT
IQ = 10µA
RL = 1MΩ, TA = +25°C
RL = 1MΩ, 0°C ≤ TA ≤
+70°C
-1.3
-0.3
±0.98
±0.96
ICL76XXB
MIN
TYP
MAX
5
7
UNITS
mV
15
µV/°C
0.5
30
pA
300
1.0
50
pA
500
-0.4
+0.6
V
-1.1
+0.6
V
-1.3
-0.3
V
±0.98
V
±0.96
4 _______________________________________________________________________________________