English
Language : 

DG444CJ Datasheet, PDF (4/8 Pages) Maxim Integrated Products – Improved, Quad, SPST Analog Switches
Improved, Quad, SPST Analog Switches
ELECTRICAL CHARACTERISTICS—Single Supply
(V+ = 12V, V- = 0V, VL = 5V, GND = 0V, VINH = 2.4V, VINL = 0.8V, TA = TMIN to TMAX, unless otherwise noted.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP
(Note 2)
MAX
UNITS
SWITCH
Analog Signal Range
VANALOG (Note 3)
0
12
V
Drain-Source
On-Resistance
rDS(ON)
V+ = 10.8V,
VL = 5.25V,
VD = 3V, 8V,
IS = -10mA
TA = +25°C
TA = TMIN to TMAX
100
160
Ω
200
SUPPLY
Power-Supply Range
V+, V-
10.8
24.0
V
Power-Supply Current
I+
All channels on or off,
VIN = 0V or 5V
Negative Supply Current
I-
All channels on or off,
VIN = 0V or 5V
TA = +25°C
-1 0.001
1
µA
TA = TMIN to TMAX
-5
5
TA = +25°C
-1 -0.0001 1
µA
TA = TMIN to TMAX
-5
5
Logic Supply Current
Ground Current
DYNAMIC
IL
IGND
All channels on or off,
VIN = 0V or 5V
All channels on or off,
VIN = 0V or 5V
TA = +25°C
-1 0.001
1
µA
TA = TMIN to TMAX
-5
5
TA = +25°C
-1 -0.0001 1
µA
TA = TMIN to TMAX
-5
5
Turn-On Time
tON VS = 8V, Figure 2
TA = +25°C
300
400
ns
Turn-Off Time
tOFF VS = 8V, Figure 2
TA = +25°C
60
200
ns
Charge Injection (Note 3) Q
CL = 1nF, VGEN = 0V,
RGEN = 0Ω, Figure 3
TA = +25°C
5
10
pC
Note 2: Typical values are for design aid only, are not guaranteed and are not subject to production testing. The algebraic convention,
where the most negative value is a minimum and the most positive value a maximum, is used in this data sheet.
Note 3: Guaranteed by design.
Note 4: On-resistance match between channels and flatness are guaranteed only with bipolar-supply operation. Flatness is defined
as the difference between the maximum and the minimum value of on-resistance as measured at the extremes of the speci-
fied analog signal range.
Note 5: Leakage parameters IS(OFF), ID(OFF), ID(ON), and IS(ON), are100% tested at the maximum rated hot temperature and guaranteed at +25°C.
Note 6: Off-Isolation Rejection Ratio = 20log (VD/VS), VD = output, VS = input to off switch.
Note 7: Between any two switches.
__________________________________________Typical Operating Characteristics
(TA = +25°C, unless otherwise noted.)
ON LEAKAGE CURRENTS
OFF LEAKAGE CURRENTS
SWITCHING THRESHOLD vs.
BIPOLAR SUPPLY VOLTAGE
2
1
3.5
1
TA = +125°C
0
0.5
TA = +125°C
3.0
2.5
IN HI MIN
0
2.0
TA = +85°C
-1
V+ = 15V
V- = -15V
-2
-15 -10 -5
0
5 10 15
VS, VD (V)
-0.5
TA = +85°C
V+ = 15V
V- = -15V
-1
-15 -10 -5 0
5 10 15
VS, VD (V)
1.5
IN LOW MAX
0.5
0
±5
±10
±15
±20
BIPOLAR SUPPLY VOLTAGE (V)
4 _______________________________________________________________________________________