English
Language : 

MAX34446 Datasheet, PDF (34/36 Pages) Maxim Integrated Products – PMBus Power-Supply Data Logger Calculates Power Consumption
MAX34446
PMBus Power-Supply Data Logger
Applications Information
Power-Supply Decoupling
To achieve the best results when using the device,
decouple the VDD power supply with a 0.1µF capacitor.
Use a high-quality, ceramic, surface-mount capacitor
if possible. Surface-mount components minimize lead
inductance, which improves performance, and ceram-
ic capacitors tend to have adequate high-frequency
response for decoupling applications.
Decouple the REG25 and REG18 regulator outputs using
1µF and 10nF capacitors (one each per output).
Open-Drain Pins
SCL, SDA, FAULTn, and PGn (when set in MFR_MODE)
are open-drain pins and require external pullup resistors
connected to VDD to realize high-logic levels.
Ordering Information
PART
MAX34446ETL+
MAX34446ETL+T
TEMP RANGE
-40NC to +105NC
-40NC to +105NC
PIN-PACKAGE
40 TQFN-EP*
40 TQFN-EP*
+Denotes a lead(Pb)-free/RoHS-compliant package.
T = Tape and reel.
*EP = Exposed pad.
Package Information
For the latest package outline information and land patterns
(footprints), go to www.maxim-ic.com/packages. Note that a
“+”, “#”, or “-” in the package code indicates RoHS status only.
Package drawings may show a different suffix character, but
the drawing pertains to the package regardless of RoHS status.
PACKAGE
TYPE
40 TQFN-EP
PACKAGE
CODE
T4066+2
OUTLINE LAND PATTERN
NO.
NO.
21-0141
90-0053
���������������������������������������������������������������� Maxim Integrated Products   34