English
Language : 

MAX6642_09 Datasheet, PDF (3/14 Pages) Maxim Integrated Products – ±1°C, SMBus-Compatible Remote/Local Temperature Sensor with Overtemperature Alarm
±1°C, SMBus-Compatible Remote/Local
Temperature Sensor with Overtemperature Alarm
ELECTRICAL CHARACTERISTICS (continued)
(VCC = +3.0V to +5.5V, TA = -40°C to +125°C, unless otherwise specified. Typical values are at VCC = +3.3V and TA = +25°C.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
SMBus-COMPATIBLE INTERFACE (SCLK and SDA)
Logic Input Low Voltage
VIL
Logic Input High Voltage
Input Leakage Current
VIH
ILEAK
VCC = 3.0V
VIN = GND or 5.5V
Output Low Sink Current
Input Capacitance
IOL
VOL = 0.6V
CIN
SMBus TIMING (Note 2)
Serial Clock Frequency
fSCLK (Note 3)
Bus Free Time Between STOP
and START Condition
tBUF
MIN TYP MAX UNITS
0.8
V
2.2
V
-1
+1
µA
6
mA
5
pF
100
kHz
4.7
µs
START Condition Setup Time
4.7
µs
Repeat START Condition Setup
Time
tSU:STA 90% to 90%
50
ns
START Condition Hold Time
STOP Condition Setup Time
Clock Low Period
Clock High Period
Data Setup Time
Receive SCLK/SDA Rise Time
Receive SCLK/SDA Fall Time
Pulse Width of Spike Suppressed
SMBus Timeout
tHD:STA
tSU:STO
tLOW
tHIGH
tHD:DAT
tR
tF
tSP
tTIMEOUT
10% of SDA to 90% of SCLK
90% of SCLK to 90% of SDA
10% to 10%
90% to 90%
(Note 4)
SDA low period for interface reset
4
µs
4
µs
4.7
µs
4
µs
250
µs
1
µs
300
ns
0
50
ns
20
28
40
ms
Note 1: All parameters tested at TA = +25°C. Specifications over temperature are guaranteed by design.
Note 2: Timing specifications guaranteed by design.
Note 3: The serial interface resets when SCLK is low for more than tTIMEOUT.
Note 4: A transition must internally provide at least a hold time to bridge the undefined region (300ns max) of SCLK’s falling edge.
_______________________________________________________________________________________ 3