English
Language : 

MAX15061 Datasheet, PDF (3/16 Pages) Maxim Integrated Products – 80V, 300mW Boost Converter and Current Monitor for APD Bias Applications
80V, 300mW Boost Converter and Current
Monitor for APD Bias Applications
ELECTRICAL CHARACTERISTICS (continued)
(VIN = VPWR = 3.3V. VSHDN = 3.3V. CIN = CPWR = 10μF. CCP = 10nF, VCNTRL = VIN. VRLIM = 0V. VPGND = VSGND = 0V. VBIAS = 40V.
APD = unconnected. CLAMP = unconnected. ILIM = unconnected, MOUT = unconnected. TA = TJ = -40°C to +125°C, unless other-
wise noted. Typical values are at TA = +25°C.) (Note 2)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Soft-Start Duration
8
ms
Soft-Start Steps
CONTROL INPUT (CNTRL)
(0.25 x ILIM_LX) to ILIM_LX
32
Steps
Maximum Control Input-Voltage
Range
FB set point is regulated to VCNTRL
1.25
V
CURRENT MONITOR
Bias Voltage Range
Bias Quiescent Current
Voltage Drop
Dynamic Output Resistance at
MOUT
MOUT Output Leakage
VBIAS
IBIAS
VDROP
RMOUT
IAPD = 500nA
IAPD = 2mA
IAPD = 2mA, VDROP = VBIAS - VAPD
IAPD = 500nA
IAPD = 2.5mA
APD is unconnected
10
76
V
100
μA
3.2
mA
1
V
1
GΩ
890
MΩ
1
nA
Output Clamp Voltage
VMOUT -
VCLAMP
Forward diode current = 1mA
0.5
0.73 0.95
V
Output Clamp Leakage Current
VBIAS = VCLAMP = 76V
1
nA
Output-Voltage Range
VMOUT
10V ≤ VBIAS ≤ 76V, 0 ≤ IAPD ≤ 1mA, clamp
is unconnected
VBIAS -
1V
V
Current Gain
IMOUT/IAPD
IAPD = 500nA
IAPD = 2mA
0.1
0.0965 0.1 0.1035
Power-Supply Rejection Ratio
APD Input Current Limit
Current-Limit Adjustment Range
Power-Up Settling Time
PSRR
ILIM_APD
tS
(ΔIMOUT/IMOUT)/ΔVBIAS,
VBIAS = 10V to 76V
(Note 3)
IAPD = 500nA
IAPD = 5μA to
1mA
VAPD = 35V, RLIM = 3.3kΩ
12.45kΩ ≥ RLIM ≥ 2.5kΩ
IMOUT settles to within
0.1%, 10nF connected
from APD to ground
IAPD = 500nA
IAPD = 2.5mA
-1000 +300 +1500
-250
3.15
1
+24 +250
3.75 4.35
5
7.5
90
LOGIC INPUTS/OUTPUTS
SHDN Input-Voltage Low
SHDN Input-Voltage High
ILIM Output-Voltage Low
ILIM Output Leakage Current
THERMAL PROTECTION
Thermal Shutdown
Thermal Shutdown Hysteresis
VIL
VIH
VOL
ILIM = 2mA
IOH
VILIM = 11V
Temperature rising
0.8
2.4
0.3
1
+160
10
Note 2: All minimum/maximum parameters are tested at TA = +125°C. Limits over temperature are guaranteed by design.
Note 3: Guaranteed by design and not production tested.
ppm/V
mA
mA
ms
μs
V
V
V
μA
°C
°C
_______________________________________________________________________________________ 3