English
Language : 

MAX14575AEVKIT Datasheet, PDF (3/8 Pages) Maxim Integrated Products – Evaluate Preselected Threshold or Adjustable Threshold by Simple Jumper Configuration
MAX14575A–MAX14575C
Evaluation Kits
Evaluate: MAX14575A/MAX14575AL/
MAX14575B/MAX14575C
Power Supply
The EV kit peripherals are powered by a user-supplied
USB port at J1 or by a 5V DC power supply connected
between VEXT and GND. Jumper JU3’s position selects
the power source. With a shunt shorting pins 1-2 on JU3,
the EV kit is powered at VEXT, while a shunt shorting pins
1-3 means that the EV kit is powered by the supply pres-
ent at the input of the device. Placing the shunt on pins
1-4 on JU3 allows the peripheral devices to be powered
from an external power supply connected at TP3. The
device must always be powered by an external supply
connected at TP6 or BP1. See Table 1 for jumper settings.
Flag Indicator LED
The EV kit includes a built-in LED to give visual notifica-
tion of an overcurrent fault. If jumper JU10 has a shunt
installed at 1-2 and jumper JU2 has no shunt installed,
then an overcurrent fault causes LED2 to glow red. See
Table 1 for jumper settings.
Preset and Adjustable Current Limits
The EV kit includes three common overcurrent limits
as jumper-configurable options, as well as a fourth
jumper-configurable option for an adjustable limit. Set the
current limit to 250mA and install a shunt across pins 1-2
on jumper JU1. For the 1.5A current limit, install a shunt
across pins 3-4 on JU1. For the 2.5A current limit or the
adjustable limit, install a shunt across pins 5-6 or 7-8 on
JU1, respectively. The adjustable limit is set using the
potentiometer (R16). See Table 1 for jumper settings.
Table 1. Jumper Settings (JU1–JU3, JU5, JU10, JU11)
JUMPER
JU1
JU2
JU3
JU5
JU10
JU11
*Default position.
SHUNT POSITION
1-2
3-4*
5-6
7-8
1-2
Not installed*
1-2*
1-3
1-4
1-2*
Not installed
1-2*
Not Installed
1-2
Not installed*
DESCRIPTION
250mA current limit
1.5A current limit
2.5A current limit
Adjustable current limit (adjust current limit with R16)
Force flag
Normal operation
Peripherals are powered by USB (J1)
Peripherals are powered by the same supply as the device
Peripherals are powered by an external 5V supply
Enables the device
Disables the device
Enables the fault indicator LED (LED2)
Disables the fault indicator LED (LED2)
Shorts input and output of the device
Normal operation
www.maximintegrated.com
Maxim Integrated │  3