English
Language : 

MAX11080 Datasheet, PDF (26/27 Pages) Maxim Integrated Products – 12-Channel, High-Voltage Battery-Pack Fault Monitor
12-Channel, High-Voltage Battery-Pack
Fault Monitor
Table 4. FEMA Analysis (Note 5) (continued)
PIN
NUMBER
29
30
NAME
ACTION
EFFECT
AGND
AGND
Open (or Disconnected) No effect.
Short to Pin 30
No effect.
Open (or Disconnected) No effect.
Short to Pin 31
If pin TOPSEL is set high (VAA), it causes the short between VAA and AGND.
ALRML is low.
There is no effect if TOPSEL is set low.
If the part is the topmost device in the daisy chain, the ALRML is set high as
Open (or Disconnected) the state of TOPSEL is low (internally pulled down).
31
TOPSEL
There are no other effects as the state of the pin stays the same (both low).
No effect if TOPSEL is set low.
Short to Pin 32
If TOPSEL is set high, it causes the short between VAA and AGND and ALRML
is low.
Open (or Disconnected) No effect.
32
AGND
Short to Pin 33
No effect.
Open (or Disconnected) No effect.
33
N.C.
Short to Pin 34
No effect.
ALRMU is internally pulled up to VDDU. There is no effect to the topmost
device. Otherwise, the communication of the chain is broken and the alarm
Open (or Disconnected) signal from the parts close to the topmost device are not passed through.
Since ALRML is a reflection of ALRMU, the state of ALRML is high for the no-
34
ALRMU
alarm state.
Short to Pin 35
No effect for the topmost device. Otherwise, the communication of the chain is
broken and the alarm signal from the parts close to the topmost are not
passed through. Since ALRML is a reflection of ALRMU, the state of ALRML is
low for the no-alarm state.
35
GNDU Open (or Disconnected) The ALRML goes high. VDDU floats down approximately 4V. (See Note 8.)
Short to Pin 36
The ALRML is high. (See Note 8).
Open (or Disconnected) ALRML goes high. HV is approximately 0.4V below DCIN. (See Note 8.)
36
VDDU
Short to Pin 37
ALRML goes high. VDDU is approximately 0.5V lower than GNDU.
(See Note 8.)
Open (or Disconnected) ALRML goes high. VDDU and HV collapse.
37
CP-
Short to Pin 38
ALRML goes high. VDDU is approximately 0.5V lower than GNDU.
(See Note 8.)
38
CP+ Open (or Disconnected) ALRML goes high. VDDU and HV collapse. (See Note 8.)
Note 5: If the cell voltage is within the monitor range, the heartbeat signal on the ALRML resumes once the fault condition is
removed.
Note 6: The voltage level of high is equal to VAA and low is equal to AGND.
Note 7: Even if the pin has internal pulldown, the pulldown is very weak and the pin should be tied to AGND for logic 0 setting.
Note 8: VDDU - GNDU = 3.3 - V and HV - DCIN = 3.6V for the typical configuration. When VDDU and HV collapse, VDDU - GNDU ≈
0 - V and HV - DCIN ≈ -0.4V.
26 ______________________________________________________________________________________