English
Language : 

MAX6514_11 Datasheet, PDF (2/8 Pages) Maxim Integrated Products – Low-Cost, 2.7V to 5.5V Temperature Switches in a SOT23
Low-Cost, 2.7V to 5.5V Temperature Switches
in a SOT23
ABSOLUTE MAXIMUM RATINGS
All Voltages Are Referenced to GND
VCC ..........................................................................-0.3V to +6V
TOVER, TUNDER (open drain)................................ -0.3V to +6V
TOVER, TUNDER (push-pull)....................... -0.3V to VCC + 0.3V
HYST .............................................................-0.3V to VCC + 0.3V
Continuous Power Dissipation
SOT23 (derate 3.1mW/°C above +70°C) .....................247mW
Operating Temperature Range ........................-55°C to +125°C
Junction Temperature ..................................................... +150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) ................................ +300°C
Soldering Temperature ....................................................+260°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VCC = 2.7V to 5.5V, RPULLUP = 100kΩ, (open-drain output only), TA = -55°C to +125°C, unless otherwise noted. Typical values are
at TA = +25°C.) (Note 1)
PARAMETER
Supply Voltage Range
SYMBOL
VCC
CONDITIONS
MIN TYP MAX UNITS
2.7
5.5
V
Supply Current
Hot-temperature thresholds
(+35°C to +115°C)
ICC
Cold-temperature thresholds
(-45°C to +15°C)
22
40
µA
40
Temperature Threshold Accuracy
(Note 2)
ΔTTH
-15°C to +65°C
+75°C to +115°C
-45°C to -25°C (Note 3)
-1.5
+1.5
-2.5
+2.5
°C
-3
+3
Temperature Threshold
Hysteresis
HYST Input Threshold (Note 4)
Logic Output Voltage High
(Push-Pull)
Logic Output Voltage Low
(Push-Pull and Open Drain)
THYST
VIH
VIL
VOH
VOL
HYST = VCC
HYST = GND
ISOURCE = 500µA, VCC > 2.7V
ISOURCE = 800µA, VCC > 4.5V
ISINK = 1.2mA, VCC > 2.7V
ISINK = 3.2mA, VCC > 4.5V
2
°C
10
0.8 x VCC
V
0.2 x VCC
0.8 x VCC
V
VCC - 1.5
0.3
V
0.4
Open-Drain Output Leakage
Current
VCC = 2.7V, open-drain output = 5.5V
10
nA
Note 1: 100% production tested at TA = +25°C. Specifications over temperature are guaranteed by design.
Note 2: The MAX6514/MAX6515 are available with internal factory-programmed temperature trip thresholds from -45°C to +15°C
and +35°C to +115°C in 10°C increments.
Note 3: VCC must be greater than 4.5V for a switching threshold of -45°C.
Note 4: Guaranteed by design.
2 _______________________________________________________________________________________