English
Language : 

MAX5921 Datasheet, PDF (2/18 Pages) Maxim Integrated Products – -48V Hot-Swap Controllers with External RSENSE and High Gate Pulldown Current
-48V Hot-Swap Controllers with External
RSENSE and High Gate Pulldown Current
ABSOLUTE MAXIMUM RATINGS
All Voltages Are Referenced to VEE, Unless Otherwise Noted
Supply Voltage (VDD - VEE )................................-0.3V to +100V
DRAIN, PWRGD, PWRGD ....................................-0.3V to +100V
PWRGD to DRAIN .............................................… -0.3V to +95V
PWRGD to VDD .......................................................-95V to +85V
SENSE (Internally Clamped) .................................-0.3V to +1.0V
GATE (Internally Clamped) ....................................-0.3V to +18V
UV and OV..............................................................-0.3V to +60V
Current into SENSE...........................................................+40mA
Current into GATE...........................................................+300mA
Current into Any Other Pin................................................+20mA
Continuous Power Dissipation (TA = +70°C)
8-Pin SO (derate 5.9mW/°C above +70°C)..................471mW
Operating Temperature Range ...........................-40°C to +85°C
Junction Temperature .....................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VEE = 0V, VDD = 48V, TA = -40°C to +85°C, unless otherwise noted. Typical values are at TA = +25°C, unless otherwise noted.) (Notes 1, 4)
PARAMETER
SYMBOL
CONDITIONS
MIN
POWER SUPPLIES
Operating Input Voltage Range
VDD
20
Supply Current
IDD
Current into VDD with UV = 3V, OV, DRAIN,
SENSE = VEE, GATE = floating
GATE DRIVER AND CLAMPING CIRCUITS
Gate Pullup Current
Gate Pulldown Current
IPU
GATE drive on, VGATE = VEE
-30
IPD
VSENSE - VEE = 100mV, VGATE = 2V (Note 2) 24
External Gate Drive
GATE to VEE Clamp Voltage
∆VGATE VGATE - VEE, steady state, 20V ≤ VDD ≤ 80V 10
VGSCLMP VGATE - VEE, IGS = 30mA
15
CIRCUIT BREAKER
Current-Limit Trip Voltage
VCL
VCL = VSENSE - VEE
40
SENSE Input Current
ISENSE VSENSE = 50mV
-1
UNDERVOLTAGE LOCKOUT
TYP MAX UNITS
80
V
0.7
2
mA
-45
-60
µA
50
70
mA
13.5
18
V
16.4
18
V
50
60
mV
-0.2
0
µA
Supply Internal Undervoltage
Lockout Voltage High
VUVLOH VDD increasing
13.8 15.4 17.0
V
Supply Internal Undervoltage
Lockout Voltage Low
UV INPUT
UV High Threshold
UV Low Threshold
UV Hysteresis
UV Input Current
OV INPUT
OV High Threshold
OV Low Threshold
OV Voltage Reference Hysteresis
OV Input Current
VUVLOL VDD decreasing
VUVH
VUVL
VUVHY
IINUV
UV voltage increasing
UV voltage decreasing
UV = VEE
VOVH
VOVL
VOVHY
IINOV
OV voltage rising
OV voltage decreasing
OV = VEE
11.8 13.4 15.0
V
1.240 1.255 1.270
V
1.105 1.125 1.145
V
130
mV
-0.5
0
µA
1.235 1.255 1.275
V
1.189 1.205 1.221
V
50
mV
-0.5
0
µA
2 _______________________________________________________________________________________