English
Language : 

MAX3172 Datasheet, PDF (2/19 Pages) Maxim Integrated Products – +3.3V Multiprotocol Software-Selectable Cable Terminators and Transceivers
+3.3V Multiprotocol Software-Selectable
Cable Terminators and Transceivers
ABSOLUTE MAXIMUM RATINGS
(All voltages referenced to GND unless otherwise noted.)
Supply Voltages
VCC ......................................................................-0.3V to +4V
V+ (Note 1) ..........................................................-0.3V to +7V
V- (Note 1) ...........................................................+0.3V to -7V
V+ to V- (Note 1) ...............................................................13V
Logic Input Voltages
M0, M1, M2, DCE/DTE, INVERT, T4IN ................-0.3V to +6V
Logic Output Voltages
R4OUT...................................................-0.3V to (VCC + 0.3V)
Short-Circuit Duration............................................Continuous
Transmitter Outputs
T4OUT ................................................................-15V to +15V
Short-Circuit Duration ........................................................60s
Receiver Input
R4INA .................................................................-15V to +15V
Termination Network Inputs (applied individually)
R_A, R_B ............................................................-15V to +15V
Continuous Power Dissipation (TA = +70°C)
28-Pin SSOP (derate 9.52mW/°C above +70°C) ........762mW
Operating Temperature Range
MAX3172CAI/MAX3174CAI ...............................0°C to +70°C
Junction Temperature ......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Note 1: V+ and V- can have maximum magnitudes of 7V, but their absolute difference cannot exceed 13V.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VCC = +3.3V ± 5%, TA = TMIN to TMAX. Typical values are at VCC = +3.3V, TA = +25°C, unless otherwise noted. See Note 2 for V+
and V- input voltage conditions.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
DC CHARACTERISTICS
Supply Current
(Digital Inputs = GND or VCC)
All modes V.10 receiver inactive
ICC
All modes V.10 receiver active
No-cable mode
80
200
µA
400
750
0.2
1.0
V+ Supply Current
(T4IN = GND)
V.10/V.11/V.28/V.35 modes unloaded
IV+
V.10/V.11 modes T4OUT loaded
0.5
2.5
mA
11.0 14.0
V.28/V.35 modes T4OUT loaded
3.0
5.0
No-cable mode
-0.4 -1.0
V- Supply Current
(T4IN = VCC)
V.10/V.11/V.28/V.35 modes unloaded
IV-
V.10/V.11 modes T4OUT loaded
-0.8 -2.5
mA
-11.0 -14.0
V.28/V.35 modes T4OUT loaded
-3.0 -5.0
TERMINATOR NETWORKS (R_A, R_B)
Differential-Mode Impedance
V.35 Mode
Figure 1, -2V ≤ VCM ≤ +2V
90
104
110
Ω
Common-Mode Impedance
V.35 Mode
Figure 2, -2V ≤ VCM ≤ +2V
135
153
165
Ω
Differential-Mode Impedance
V.11 Mode
Figure 1, -7V ≤ VCM ≤ +7V
100
104
110
Ω
Network OFF Impedance
IZ
Switches open, -15V ≤ VA ≤ +15V, VB = VA,
VB = GND or VB floating
50
150
kΩ
LOGIC INPUTS (M0, M1, M2, INVERT, DCE/DTE, T4IN)
Input High Voltage
VIH
2.0
V
Input Low Voltage
VIL
0.8
V
Logic Input Current
IIH, IIL VIN = VCC or GND
±1
µA
2 _______________________________________________________________________________________